23
4 Mounting
VEGAPULS 64 • 4 … 20 mA/HART - two-wire
51141-EN-160815
Information:
When mounting on longer sockets, we recommend carrying out a
false signal suppression (see chapter "
Parameter adjustment
").
You will find recommended values for socket heights in the following
illustration or the tables. The values come from typical applications.
Deviating from the proposed dimensions, also longer sockets are
possible, however the local conditions must be taken into account.
d
h
Fig. 16: Socket mounting with deviating socket dimensions
Socket diameter d
Socket length h
40 mm
50 mm
≤ 150 mm
80 mm
≤ 200 mm
100 mm
≤ 300 mm
150 mm
≤ 500 mm
Socket diameter d
Socket length h
1½"
2"
≤ 5.9 in
3"
≤ 7.9 in
4"
≤ 11.8 in
6"
≤ 19.7 in
The mounting socket should be as short as possible and its end
rounded. This reduces false echoes from the vessel mounting socket.
Fig. 17: Recommended socket mounting
In case of good reflective properties of the medium, you can also
mount VEGAPULS 64 on a longer socket piece.
Information:
When mounting on longer sockets, we recommend carrying out a
false signal suppression (see chapter "
Parameter adjustment
").
Socket with flange con-
nection