7.2 Diagnostics
The source holder does not have any diagnostics that alert users to potential
problems. However, emergency guidelines as outlined in the
Radiation Safety
Manual
provide steps you can take for the following emergency situations:
•
Stuck Shutter or Inoperable Cable
•
Loss or Theft
•
Entering a Tank or Vessel
•
Fall, Collision, or Fire
7.3 Troubleshooting
The source holder is extremely reliable, but errors can occur during operation.
Some of those potential problems are caused by the following:
Item
Action to Take
Abandoned or
discarded source
In the United States, contact the U.S. NRC or an
agreement state.
Damaged or failed
source
Retract the capsules into the shielded position, if
possible and contact VEGA Americas Nuclear
Services.
Missing or broken lock Do not remove the source from the crate or mount the
source. If the source is already mounted, contact
VEGA Americas Nuclear Services.
Cable not operating
correctly
Contact VEGA Americas Nuclear Services.
Source leak
Evacuate the immediate area and control entry to the
area. Contact VEGA Americas Nuclear Services.
Improper Handling
Contact VEGA Americas Nuclear Services.
Improper or damaged
shielding
Contact VEGA Americas Nuclear Services.
Improper mounting
Contact VEGA Americas Nuclear Services.
Improper installation
Contact VEGA Americas Nuclear Services.
Содержание SHLM MI4
Страница 1: ...Operating Instructions SHLM MI4 Source Holder Document ID 48642 Nuclear...
Страница 2: ......
Страница 4: ...4 48642 US 150527 NOTES...
Страница 8: ...8 48642 US 150527 NOTES...
Страница 12: ...12 48642 US 150527 NOTES...
Страница 16: ...16 48642 US 150527 NOTES...
Страница 26: ...26 48642 US 150527 NOTES...
Страница 31: ...48642 US 150527 31 Figure 4 2 SHLM MI4 Preferred Density and Point Level Orientation...
Страница 43: ...48642 US 150527 43 Figure 5 4 Mounting Frame without Cabinet...
Страница 44: ...44 48642 US 150527 NOTES...
Страница 64: ...64 48642 US 150527 NOTES...
Страница 70: ...70 48642 US 150527 NOTES...
Страница 71: ......