48642-US-150527
51
4.
If necessary, while pushing the cable downward, use your left hand to rotate
the coil of cable through the cable guides to keep things moving smoothly.
At the Source Holder
1.
Locate the source carrier with the “T” identification. The source carrier has a
threaded end that is covered by a thread protector.
Figure 6.9
Thread Protector
2.
Rotate the thread protector to remove and to expose the connection threads
on the source carrier.
3.
Notice the jam nut that is on the source carrier.
4.
For proper connection, make sure that the jam nut is threaded fully against
the source carrier to expose the maximum thread.
Figure 6.10
Connecting the Source Carrier
1. Swivel Fitting
2. Jam Nut
3. Hole Used to Assist with Cable Attachment
4. Source Carrier
Содержание SHLM MI4