6.8.5 Capture Screen
Fiber Scope Capture Screen
•
Freeze / Resume:
Stops the real time video so users can look at the static picture.
•
Analysis On / OFF:
Turn the Auto Analysis ON and OFF (software option).
•
Auto Freeze:
Turn ON and OFF the ability to freeze the image automatically, when in
Focus. The default is set to OFF. To see the image after it freezes, tap Resume.
•
Rectangles / Dots:
Dots draw a red contour around scratches and defects. Rectangles
highlight scratches and defects without obstructing the view.
•
Shake:
Turn ON or OFF the ability to Auto Freeze and Analyze when probe image is
unsteady. Shake should be OFF when testing bulkhead couplers.
•
MPO mode:
Turn ON when inspecting ribbon fibers (MPO/MPT connectors). Create
New Group for each MPO ribbon and Capture to save an image for each strand.
Fiber Scope MOP mode