7.5 Making Measurements
Press
Start
and the measurement will begin according to the test parameters entered in the
Setup
menu (see
7.1 Test Setup (OTDR Setup page 1)
•
The elapsed time is indicated on the red stop button on the right side of the display. The
stop button will revert back to a green
Start
button when acquisition is complete. For V-
Scout measurements, the acquisition wavelength is also displayed.
Press
Stop
to terminate the measurement manually, if required.
Once the measurement is complete, the
Result Autosaving
screen appears to allow the
saving of measurement results. Press
OK
to autosave with the default settings.
Use the
Home
icon to get to Fiber Main Menu to select test application (OTDR, VFL, OLS,
OPM).
7.5.1 Traces Display
When a new measurement is started, only those traces will be displayed on the screen. Any
previous traces can be accessed via the
Traces
tab until unit is switched off. Upon completion,
the view will initially default to the selected test mode viewing screen (V-Scout, Event (Auto), or
Measure (Manual).
If multiple wavelengths are selected in the
Setup
menu, the measurement will be performed
using all selected wavelengths one after another without stopping and will be overlaid on
screen for comparison and review. V-Scout traces are overlaid and displayed automatically.
Содержание OTDR FX150+ Series
Страница 1: ...OTDR Series e Manual D07 00 076P RevD00 Page 1 of 109...
Страница 13: ...OTDR Series e Manual D07 00 076P RevD00 Page 13 of 109 TX300s Top View RxT 4100 OTDR Module...
Страница 16: ...OTDR Series e Manual D07 00 076P RevD00 Page 16 of 109 5 3 MTTplus Overview 5 3 1 MTTplus Side View...
Страница 18: ...OTDR Series e Manual D07 00 076P RevD00 Page 18 of 109 5 4 RXT Overview...
Страница 50: ...OTDR Series e Manual D07 00 076P RevD00 Page 50 of 109 Analysis Report pdf format...
Страница 97: ...OTDR Series e Manual D07 00 076P RevD00 Page 97 of 109 MTTplus Manual Save Image added to results...