OTDR Series
e-Manual, D07-00-
076P
-RevD00
Page 77 of 109
•
Distance Unit
– Sets metric for distance between fiber sections in viewing window (km,
kft, feet, meter, miles).
•
Splitters
– Defines splitter loss values to be applied when building the LinkMap.
Splitter Loss values
7.2.2 Pass/Fail Thresholds
Events exceeding the Pass/Fail Thresholds are highlighted in Red in the Event table. Different
Pass/Fail Thresholds values can be set for each test wavelength.
Event Loss (splice, connectors) and Reflectance threshold settings determine if a detected
anomaly should be reported and included in the event table including its event type (reflective
or non-reflective).
•
Wavelength (nm)
- Wavelength to which Pass/Fail Thresholds apply
•
Splice loss (dB)
- Non-Reflective Event Loss (fusion splices). The range for this
parameter is 0.10 dB to 9.99 dB in 0.01dB increments
•
Connector Loss (dB)
- Reflective Event Loss (connectors and mechanical splices).
The range for this parameter is 0.10 dB to 9.99 dB in 0.01 dB increments
•
Reflectance (dB)
- Events in the Event table exceeding the set Reflectance value. The
range for this parameter is -50.0 dB to -10.0 dB in 0.1 dB increments
•
Slope (dB/km)
- Average Fiber Section Loss in dB/km that exceeds the set value.
•
Total Loss (dB)
- Total fiber loss in dB for Fiber-Under-Test (FUT) that exceeds the set
value.
•
Total ORL (dB)
- Total Optical Return Loss in dB for Fiber-Under-Test (FUT) that
exceeds the set value.
•
Fiber Length (km, miles)
- Total fiber length that exceeds set value
•
Default Settings
: Resets Pass/Fail Thresholds to factory defaults
Содержание OTDR FX150+ Series
Страница 1: ...OTDR Series e Manual D07 00 076P RevD00 Page 1 of 109...
Страница 13: ...OTDR Series e Manual D07 00 076P RevD00 Page 13 of 109 TX300s Top View RxT 4100 OTDR Module...
Страница 16: ...OTDR Series e Manual D07 00 076P RevD00 Page 16 of 109 5 3 MTTplus Overview 5 3 1 MTTplus Side View...
Страница 18: ...OTDR Series e Manual D07 00 076P RevD00 Page 18 of 109 5 4 RXT Overview...
Страница 50: ...OTDR Series e Manual D07 00 076P RevD00 Page 50 of 109 Analysis Report pdf format...
Страница 97: ...OTDR Series e Manual D07 00 076P RevD00 Page 97 of 109 MTTplus Manual Save Image added to results...