EMR3 Terminal - Fueling Depot Installation
Wiring the Display Head
43
If you are replacing a Brodie, Brooks, or Neptune register install the necessary meter adaption kit as per direc-
tions in “Neptune Flow Meter Installation” on page 18.
3.
Notice the type of coupling connecting the register/preset to the meter adaptor input shaft.
4.
Look at the base of the meter register. The projecting encoder shaft has a small cotter pin inserted in it to keep
it from sliding up into the unit and a washer (P/N 011071-933). Remove this cotter pin.
Remove an identical coupling from the installation kit and attach it with an enclosed groove pin to the encoder
input shaft projecting from the base of the Display Head (make sure that you support the encoder shaft when
inserting the pin to avoid damaging the shaft).
Make sure the washer is on the shaft between the end of the coupling and the Display
Head.
5.
Remove the four cover bolts of the Display Head and lift off the cover. Put the cover and bolts aside.
6.
Orient the encoder input shaft coupling so that it ‘mates’ with the meter adaptor input shaft, then lower the
Display Head onto the meter adaptor mounting flange.
7.
Rotate the Display Head on the meter adaptor mounting flange until the display is facing in the desired
direction and check to see that the four meter adaptor flange mounting holes align with four of the eight
tapped (1/4 - 28 UNF-2B threads) mounting holes in the base of the Display Head’s housing. You may have to
rotate the Display Head right or left a little to line up four holes. Reuse the four mounting bolts and tighten
them securely.
8.
If you have the optional temperature probe, remove the existing temperature probe and replace it with the
Display Head temperature probe.
Wiring the Display Head
1.
With the Display Head cover still off, remove the nut and bushing from the top side panel cord grip connector.
Note: the maximum cable length between the Interconnection Box and the Display Head is 1000 feet (304.8
meters).
2.
Slide the cord grip nut and then the bushing over the IB cable leads. Pull enough cable through so that the
leads reach the terminal block on the display assembly and can be tie wrapped to the pulse encoder mounting
base as shown in Figure 34. Slide the tapered end of the bushing into the cord grip, then screw on the cord
grip nut and tighten securely.
3.
Attach the four-wire IB cable to the terminal block as shown in Figure 34. Attach the drain wire of the IB cable
to a grounding lug on the pulse encoder mounting base as shown in Figure 34.
When stripping wire for terminal block connections, be careful not to nick the individual strands. Also, be sure
to tighten each terminal so the wire can not be pulled out. A failure to follow either of these instructions can re-
sult in signal loss and faulty operation.
4.
If you have the optional temperature probe remove the lower cord grip nut and slide it, then the tapered
bushing, over the temperature probe cable. Pull enough cable through so that the leads reach the terminal
block on the display assembly and can be tie wrapped to the pulse encoder mounting base as shown in
Figure 34. Slide the bushing into the cord grip and then screw the cord grip nut onto the cord grip and tighten
securely.
Attach the shield of the temperature probe cable to a grounding lug on the pulse encoder mounting base.
5.
Attach each wire (no polarity) of the 2-connector temperature probe cable as shown in Figure 34.
6.
Tie wrap the IB and temp probe (if installed) cables to the pulse encoder mounting base.
Содержание EMR3 XStream-PKG
Страница 1: ...Manual No 577013 758 Revision I Installation Guide EMR3 ...
Страница 29: ...EMR3 Truck Installation C C Mode Switch Options 24 Figure 18 Display head cable connections ...
Страница 67: ......
Страница 68: ...For technical support sales or other assistance please visit www veeder com ...