![Vectornav VN-100 Скачать руководство пользователя страница 75](http://html2.mh-extra.com/html/vectornav/vn-100/vn-100_user-manual_3752294075.webp)
UM001
75
5.3
Status Registers
5.3.1
Synchronization Status
Synchronization Status
Register ID : 33
Access : Read / Write
Comment : Contains status parameters that pertaining to the communication synchronization features.
Size (Bytes): 12
Example
Response:
$VNRRG,33,2552498,0,0*6A
Offset
Name
Format
Unit Description
0
SyncInCount
uint32
-
Keeps track of the number of times that the SyncIn
trigger even has occured. This register can be used to
correlate the attitude to an event on an external
system such as a camera or GPS.
It is also possible to have the value of this register
appended to each asynchronous data packet on the
serial bus. This can be done by setting the AsyncStatus
field in the Communication Protocol register to 1.
4
SyncInTime
uint32
µs
Keeps track of the amount of time that has elapsed
since the last SyncIn trigger event. If the SyncIn pin is
connected to the PPS (Pulse Per Second) line on a GPS
and the AsyncStatus field in the Communication
Protocol Register is set to 1, then each asynchronous
measurement will be time stamped relative to the last
received GPS measurement.
8
SyncOutCount uint32
-
Keeps track of the number of times that the SyncOut
trigger event has occurred. This register can be used to
index subsequent measurement outputs, which is
particularly useful when logging sensor data.
Writing zero to the SyncInCount or the SyncOutCount will reset the status counter. Any other value
other than zero will not have an effect. The SyncInTime is read only and cannot be reset to zero.
Содержание VN-100
Страница 1: ...UM001 1 Firmware v2 1 0 0 Document Revision 2 22 VN 100 User Manual Embedded Navigation Solutions...
Страница 9: ...UM001 9 2 Specifications 2 1 VN 100 Surface Mount Sensor SMD Electrical Pin assignments top down view...
Страница 14: ...14 UM001 2 3 VN 100 Surface Mount Sensor SMD Dimensions Measurements are in inches 2 4 VN 100 Rugged Dimensions...
Страница 102: ...102 UM001 8 3 Factory Defaults Settings Name Default Factory Value Magnetometer Calibration Control 1 3 5...
Страница 113: ...UM001 113 9 5 Factory Defaults Settings Name Default Factory Value Velocity Compensation Control 1 0 1 0 01...