UM001
67
SyncInEdge
The SyncInEdge register controls the type of edge the signal is set to trigger on. The factory default state
is to trigger on a rising edge.
SyncInEdge Mode
Value
Description
0
Trigger on rising edge
1
Trigger on falling edge
SyncInSkipFactor
The SyncInSkipFactor defines how many times trigger edges defined by SyncInEdge should occur prior to
triggering a SyncIn event. The action performed on a SyncIn event is determined by the SyncIn mode. As
an example if the SyncInSkipFactor was set to 4 and a 1 kHz signal was attached to the SyncIn pin, then
the SyncIn event would only occur at 200 Hz.
SyncOutMode
The SyncOutMode register controls the behavior of the SyncOut pin. If this is set to IMU then the SyncOut
will start the pulse when the internal IMU sample loop starts. This mode is used to make a sensor the
Master in a multi-sensor network array. If this is set to IMU_READY mode then the pulse will start when
IMU measurements become available. If this is set to INS mode then the pulse will start when attitude
measurements are made available. Changes to this register take effect immediately.
SyncOutMode
Mode
Value Description
NONE
0
None
IMU_START
1
Trigger at start of IMU sampling
IMU_READY 2
Trigger when IMU measurements are available
INS
3
Trigger when attitude measurements are available
SyncOutPolarity
The SyncOutPolarity register controls the polarity of the output pulse on the SyncOut pin. Changes to this
register take effect immediately.
SyncOutPolarity
Value
Description
0
Negative Pulse
1
Positive Pulse
SyncOutSkipFactor
The SyncOutSkipFactor defines how many times the sync out event should be skipped before actually
triggering the SyncOut pin.
SyncOutPulseWidth
The SyncOutPulseWidth field controls the desired width of the SyncOut pulse. The default value is
100,000,000 (100 ms).
Содержание VN-100
Страница 1: ...UM001 1 Firmware v2 1 0 0 Document Revision 2 22 VN 100 User Manual Embedded Navigation Solutions...
Страница 9: ...UM001 9 2 Specifications 2 1 VN 100 Surface Mount Sensor SMD Electrical Pin assignments top down view...
Страница 14: ...14 UM001 2 3 VN 100 Surface Mount Sensor SMD Dimensions Measurements are in inches 2 4 VN 100 Rugged Dimensions...
Страница 102: ...102 UM001 8 3 Factory Defaults Settings Name Default Factory Value Magnetometer Calibration Control 1 3 5...
Страница 113: ...UM001 113 9 5 Factory Defaults Settings Name Default Factory Value Velocity Compensation Control 1 0 1 0 01...