UM001
31
4
User Configurable Binary Output Messages
The VN-100 supports 3 separate user configurable binary output messages available on the serial
interface. Each message can be configured by the user to contain any of the available output
measurement types from the IMU, NavState, or NavFilter subsystems. The device can be configured to
asynchronously output each message at a fixed rate based upon a divisor of the IMU internal sampling
rate (IMU Rate).
4.1
Available Output Types
All real-time measurements either measured or estimated by the VN-100 are available using the user
output messages. The different output types are organized into 6 separate output groups. The first group
is a combination of the most common outputs from the remaining groups. The other groups are shown
below.
Binary Outputs
4.2
Configuring the Output Types
Configuration of the 3 output messages is performed using the User Output Configuration Registers
(Register 75-77). There are 3 separate configuration registers, one for each available output message.
The Binary Output Register 1-3 in the System subsystem section describes in more detail the format for
these registers. In each of these configuration registers the user can select which output types they want
the message to include by specifying the OutputGroup and the OutputFields parameters.
4.2.1
OutputGroup
The OutputGroup and OutputFields parameters consist of variable length arguments to allow conciseness
where possible and expandability where necessary.
The OutputGroup parameter consists of one or more bytes which are used to identify the Binary Output
Groups from which data will be selected for output (see OutputField parameter). Each 8-bit byte consists
of seven group selection bits (Bit 0 through Bit 6) and an extension bit (Bit 7). The extension bit in each
byte is used to indicate the presence of a following continuation byte to select additional (higher-
numbered) groups. The first byte selects Groups 1-7 (with bit offsets 0-6, respectively), the second byte
Time
•TimeStartup
•TimeGps
•GpsTow
•GpsWeek
•TimeSyncIn
•TimeGpsPps
•TimeUTC
•SyncInCnt
•SyncOutCnt
•TimeStatus
IMU
•Status
•UncompMag
•UncompAccel
•UncompAngularRate
•Temp
•Pres
•DeltaTheta
•DeltaVel
•Mag
•Accel
•AngularRate
•SatFlags
Attitude
•Status
•YawPitchRoll
•Quaternion
•DCM
•MagNed
•AccelNed
•LinearAccelBody
•LinearAccelNed
•YprU
Содержание VN-100
Страница 1: ...UM001 1 Firmware v2 1 0 0 Document Revision 2 22 VN 100 User Manual Embedded Navigation Solutions...
Страница 9: ...UM001 9 2 Specifications 2 1 VN 100 Surface Mount Sensor SMD Electrical Pin assignments top down view...
Страница 14: ...14 UM001 2 3 VN 100 Surface Mount Sensor SMD Dimensions Measurements are in inches 2 4 VN 100 Rugged Dimensions...
Страница 102: ...102 UM001 8 3 Factory Defaults Settings Name Default Factory Value Magnetometer Calibration Control 1 3 5...
Страница 113: ...UM001 113 9 5 Factory Defaults Settings Name Default Factory Value Velocity Compensation Control 1 0 1 0 01...