68
UM001
5.2.10
Communication Protocol Control
Communication Protocol Control
Register ID : 30
Access :
Read /
Write
Comment : Contains parameters that controls the communication protocol used by the sensor.
Size (Bytes): 7
Example Response: $VNRRG,30,0,0,0,0,1,0,1*6C
Offset Name
Format
Unit
Description
0
SerialCount
uint8
-
Provides the ability to append a counter or time to the end
of the serial asynchronous messages.
1
SerialStatus
uint8
-
Provides the ability to append the status to the end of the
serial asynchronous messages.
2
SPICount
uint8
-
Provides the ability to append a counter to the end of the
SPI packets.
3
SPIStatus
uint8
-
Provides the ability to append the status to the end of the
SPI packets.
4
SerialChecksum
uint8
-
Choose the type of checksum used for serial
communications.
5
SPIChecksum
uint8
-
Choose the type of checksum used for the SPI
communications.
6
ErrorMode
uint8
-
Choose the action taken when errors are generated.
Содержание VN-100
Страница 1: ...UM001 1 Firmware v2 1 0 0 Document Revision 2 22 VN 100 User Manual Embedded Navigation Solutions...
Страница 9: ...UM001 9 2 Specifications 2 1 VN 100 Surface Mount Sensor SMD Electrical Pin assignments top down view...
Страница 14: ...14 UM001 2 3 VN 100 Surface Mount Sensor SMD Dimensions Measurements are in inches 2 4 VN 100 Rugged Dimensions...
Страница 102: ...102 UM001 8 3 Factory Defaults Settings Name Default Factory Value Magnetometer Calibration Control 1 3 5...
Страница 113: ...UM001 113 9 5 Factory Defaults Settings Name Default Factory Value Velocity Compensation Control 1 0 1 0 01...