UM001
55
5.1.6
Firmware Update Command
This command is used to enter the boot loader for performing firmware updates. Upon receiving this
command on serial port 1, the VN-100 will enter into firmware reprogramming mode. The easiest method
of updating firmware is to use one of the VectorNav Firmware Update Tools. If you wish however to
incorporate the ability to update the firmware into your own system, the protocol and procedure for
updating the firmware is outlined in the AN013 Firmware Update Protocol application note.
Example Firmware Update Command
Example Command
Message
UART Command
$VNFWU*XX
UART Response
$VNFWU*XX
Firmware updates are only supported on serial port 1. If you plan on using either serial port 2 as your
primary means of communicating with the sensor, it is recommended that you also provide support in
your design to communicate with the sensor using serial port 1 to facilitate firmware updates.
5.1.7
Serial Command Prompt Command
This command allows you to enter into the command prompt mode on either serial port. The command
mode supports a wide range of diagnostics and configuration options that go beyond the abilities of the
normal read/write configuration register interface.
Example Command Prompt Command
Example Command
Message
UART Command
$VNCMD*XX
UART Response
$VNCMD*XX
Содержание VN-100
Страница 1: ...UM001 1 Firmware v2 1 0 0 Document Revision 2 22 VN 100 User Manual Embedded Navigation Solutions...
Страница 9: ...UM001 9 2 Specifications 2 1 VN 100 Surface Mount Sensor SMD Electrical Pin assignments top down view...
Страница 14: ...14 UM001 2 3 VN 100 Surface Mount Sensor SMD Dimensions Measurements are in inches 2 4 VN 100 Rugged Dimensions...
Страница 102: ...102 UM001 8 3 Factory Defaults Settings Name Default Factory Value Magnetometer Calibration Control 1 3 5...
Страница 113: ...UM001 113 9 5 Factory Defaults Settings Name Default Factory Value Velocity Compensation Control 1 0 1 0 01...