ErrorMode
This field controls the type of action taken by the VN-100 when an error event occurs. If the send error
mode is enabled then a message similar to the one shown below will be sent on the serial bus when an
error event occurs.
$VNERR,03*72
Regardless of the state of the ErrorMode, the number of error events is always recorded and is made
available in the SysErrors field of the Communication Protocol Status Register in the System subsystem.
ErrorMode
Value Description
0
Ignore Error
1
Send Error
2
Send Error and set ADOR register to OFF
Example Async Messages
The following table shows example asynchronous messages with the AsyncCount and the AsyncStatus
values appended to the end.
Example Type
Message
Async Message with
AsyncCount Enabled
$VNYPR,+010.071,+000.278,-002.026,T1162704*2F
Async Message with
AsyncStatus Enabled
$VNYPR,+010.071,+000.278,-002.026,S0000*1F
Async Message with
AsyncCount and
AsyncStatus Enabled
$VNYPR,+010.071,+000.278,-002.026,T1162704,S0000*50