background image

2

IMPORTANT SAFETY INSTRUCTIONS

Read and Understand all Warnings, Cautions and Notes before operating Power City. 

Warnings alert the user to hazardous conditions that can be harmful to people. Cautions alert 

the  user  to  conditions  that  can  cause  property  damage.  Notes  are  important  operational  

information.  

KEEP THIS USER’S GUIDE FOR FUTURE USE.

JUMP-START WARNINGS AND CAUTIONS

•  There is risk of explosive gas being released when batteries are improperly charged  

  or  discharged.  Failure  to  follow  instructions  may  cause  property  damage,  explosion  

  hazard and/or personal injury

•  Do not smoke while jump-starting

•  Only attempt to jump-start a vehicle or boat in a well ventilated area

•  This  power  system  is  to  be  used  ONLY  on  vehicles  or  boats  with  12  volt  DC  

  battery systems 

•  Do not wear vinyl clothing when jump-starting a vehicle - friction can cause dangerous  

  static electricity sparks

•  Remove all metal jewelry - this can cause short circuits. Always use protective eyewear  

  when jump-starting:  contact with battery acid may cause blindness and/or severe burns.

•  Never touch Power City red and black clamps together - this can cause dangerous   

  sparks, power arcing and/or explosion

•  Do not attempt to jump-start a frozen battery

•  After use as jump-starter, turn off safety switch   

• Keep out of reach of children

•  Vehicles that have on-board computerized systems may be damaged if vehicle battery 

  is jumpstarted. Before jump-starting this type of vehicle, read the vehicle’s owner’s    

  manual to confirm that external-starting assistance is advised

•  Excessive engine cranking can damage the vehicle’s starter motor. If the engine fails to  

  start after the recommended number of attempts, discontinue jumpstart procedure and  

  look for other problems that may need to be corrected

• When  safety  switch  is  off,  Polarity  Alarm  is  enabled.  If  cables  are  connected  to  

  another battery and the alarm sounds, the cable connections must be switched. If alarm  

  sounds, do not turn on safety switch

•  If vehicle to be started has a positive grounded System (positive battery terminal is   

  connected to chassis), replace steps 9 and 10 of the jump-start procedure (below) with  

  the following steps A and B, and then proceed to step 11

    A.   Connect negative (-) black clamp to vehicle battery ‘s negative terminal.

    B.   Connect positive (+) red clamp to vehicle chassis or a solid, non-moving, metal  

        vehicle  component  or  body  part.  DO  NOT  clamp  directly  to  positive  battery  

        terminal  or moving part.

•  Replace worn or defective parts immediately - contact Vector Technical Support 

  Department at  toll-free 866-584-5504

•  Skin: if battery acid comes in contact with skin, rinse immediately with water, then wash  

  thoroughly with soap and water. If redness, pain, or irritation occurs, seek immediate  

  medical attention

•  Eyes: if battery acid comes in contact with eyes, flush eyes immediately for a minimum  

  of 15 minutes, seek immediate medical attention.

Содержание Power City DK080706

Страница 1: ...S INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 S W 30TH AVE FT LAUDERDALE FL 33312 TEL 9...

Страница 2: ...erized systems may be damaged if vehicle battery is jumpstarted Before jump starting this type of vehicle read the vehicle s owner s manual to con rm that external starting assistance is advised Exces...

Страница 3: ...4 7 Inverter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor use 11 5 2 Warnings 11 5 3 Tire In ation or products with a valve stem 12 5 4 In ate other articles without valve stem 12...

Страница 4: ...luable when it becomes necessary to locate battery terminals while preparing to jumpstart a dead battery in the dark changing a tire etc Power City is also ideal to power 12 volt DC cordless portable...

Страница 5: ...er hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter with a 120 volt AC standard type plug Operate using 23 ampere rated 12 volt acces...

Страница 6: ...nected to chassis most common 4 Make sure Power City s main unit safety switch is turned off 5 Carefully lift negative black jumper cable wire from storage channel starting at clamp end of cable 6 Squ...

Страница 7: ...the inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The green LED will not be lit under shutdown conditions Inverter shutdown is c...

Страница 8: ...s operated away from the main unit the power source must provide between 11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a batter...

Страница 9: ...age to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrect polarity the fuse will blow If the unit does not function after replacement of the fuse the unit must be r...

Страница 10: ...ece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure fr...

Страница 11: ...volt DC accessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 volt DC compressor is the ultimate compressor for all vehicles trailer tires and recreational in atables Three different sized nozz...

Страница 12: ...very rapidly 5 Insert adaptor e g needle into item to be in ated and in ate to desired pressure 6 Turn on compressor switch in ate to desired pressure or fullness refer to paragraph 5 5 7 Remove adapt...

Страница 13: ...on and during under the hood inspections See Figure 9 If an alternative 12 volt DC source is avail able the lantern can be powered from a standard 12 volt accessory socket The lantern draws 11 watts s...

Страница 14: ...sponsible manner Follow local ordinances for disposal 7 RECHARGING POWER CITY S BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid...

Страница 15: ...in their own cable storage hatch in the main unit Recharging the main unit s internal battery from an external DC power source requires the use of the DC recharge cable and the inverter power cable Se...

Страница 16: ...cement parts bulbs batteries charging adapters cables etc contact Vector Technical Support toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the lantern there are no user servicea...

Страница 17: ...Power Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 350 Watt 60 Hz 110 120 VAC Inverter Waveform Modi ed Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm...

Страница 18: ...not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents d...

Страница 19: ...19...

Страница 20: ...20 2006 VECTOR PRODUCTS INC FT LAUDERDALE FL 33312 MADE IN CHINA DK080706...

Отзывы: