4.2   PRINCIPLES OF OPERATION

The  power  inverter  converts  power  in  two  stages.  The  first  stage  is  a  DC-to-DC  conversion 

process that raises the low voltage DC at the inverter input to 145 volts DC. The second stage 

is the actual inverter stage that converts the high voltage DC into 120 volts, 60 Hz AC, Modi-

fied Sine Wave (MSW). MSW is a waveform that has characteristics similar to the sine wave 

shape of utility power. This type of waveform is suitable for most AC loads, including linear and 

switching power supplies used in electronic equipment, transformers, and motors. The modified 

sine wave produced by the power inverter has an RMS (root mean square)  voltage of 120 

volts, which is the same as standard household power. Most AC voltmeters (both digital and 

analog) are calibrated for RMS voltage under the assumption that the waveform measured will 

be a pure sine wave. These meters will NOT READ the RMS voltage of a modified sine wave  

correctly. They will read about 20 to 30 volts low when measuring the output of the power inverter. 

For accurate measurement of the output voltage of this unit, use a voltmeter marked “TRUE RMS”. 

Figure 5 compares a Modified Sine Wave with a True Sine Wave.

FIGURE 5

The Power Inverter is incorporated into the Power City main unit. It’s DC source is the main unit’s 

12 volt, 19AH battery. Power is provided to the inverter through two flat contacts on the bottom 

of the inverter. The inverter operates on stored energy in the main battery. With a full charge on 

the main battery, the inverter will supply a load of 100 watts for approximately one hour and 5 

minutes. Lower wattage loads will operate longer, higher wattage loads will operate for a shorter 

time using energy from the main battery.
When  the  inverter  is  operated  away  from  the  main  unit,  the  power  source  must  provide  

between 11 and 14.5 volts DC and must be able to supply the necessary current (amps) to operate 

the load. The power source may be a battery or a well-regulated DC power supply. To obtain a 

rough estimate of the current (in amperes) that the power source must deliver, simply divide the 

power consumption of the load (in watts AC) by 10.
Example:  If  a  load  is  rated  at  100  watts  AC,  the  power  source  must  be  able  to  deliver:  

100 / 10 = 10 amperes

CAUTION:

 The inverter must be connected only to batteries with a nominal output voltage of  

    12 volts. The unit will not operate from a 6 volt battery and will sustain permanent           

    damage if connected to a 24 volt battery.
The inverter may be used whether or not the vehicle’s engine is running. However, the inverter 

may not operate while the engine is starting since the battery voltage can drop substantially  

during engine cranking. The inverter draws less than 0.06 ampere from the battery when it is 

not supplying power to a load.

4.3   CONNECTING INVERTER TO POWER SOURCE AWAY FROM MAIN UNIT

The Inverter can be used away from the main unit by removing it from it’s mounting on the 

main unit and powering it from the Inverter power cable, located in the storage compartment 

in the back of unit.  The power inverter has two flat metal contacts that normally mate with the  

connector on the main unit. These flat contacts are connected to the inverter power cable (black 

and red color) when the inverter is removed from the unit and operated away from the unit. The 

inverter power cable comes equipped with a 12 volt DC plug. The tip of the plug is positive and 

the side contact is negative. Connect the power inverter to the power source by inserting the DC 

plug firmly into the accessory outlet of a vehicle or other DC power source. The connection to 

the accessory outlet can be improved by slightly rotating the plug in the socket. (See Figures 6 

and 7)

Содержание Power City DK080706

Страница 1: ...S INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 S W 30TH AVE FT LAUDERDALE FL 33312 TEL 9...

Страница 2: ...erized systems may be damaged if vehicle battery is jumpstarted Before jump starting this type of vehicle read the vehicle s owner s manual to con rm that external starting assistance is advised Exces...

Страница 3: ...4 7 Inverter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor use 11 5 2 Warnings 11 5 3 Tire In ation or products with a valve stem 12 5 4 In ate other articles without valve stem 12...

Страница 4: ...luable when it becomes necessary to locate battery terminals while preparing to jumpstart a dead battery in the dark changing a tire etc Power City is also ideal to power 12 volt DC cordless portable...

Страница 5: ...er hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter with a 120 volt AC standard type plug Operate using 23 ampere rated 12 volt acces...

Страница 6: ...nected to chassis most common 4 Make sure Power City s main unit safety switch is turned off 5 Carefully lift negative black jumper cable wire from storage channel starting at clamp end of cable 6 Squ...

Страница 7: ...the inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The green LED will not be lit under shutdown conditions Inverter shutdown is c...

Страница 8: ...s operated away from the main unit the power source must provide between 11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a batter...

Страница 9: ...age to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrect polarity the fuse will blow If the unit does not function after replacement of the fuse the unit must be r...

Страница 10: ...ece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure fr...

Страница 11: ...volt DC accessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 volt DC compressor is the ultimate compressor for all vehicles trailer tires and recreational in atables Three different sized nozz...

Страница 12: ...very rapidly 5 Insert adaptor e g needle into item to be in ated and in ate to desired pressure 6 Turn on compressor switch in ate to desired pressure or fullness refer to paragraph 5 5 7 Remove adapt...

Страница 13: ...on and during under the hood inspections See Figure 9 If an alternative 12 volt DC source is avail able the lantern can be powered from a standard 12 volt accessory socket The lantern draws 11 watts s...

Страница 14: ...sponsible manner Follow local ordinances for disposal 7 RECHARGING POWER CITY S BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid...

Страница 15: ...in their own cable storage hatch in the main unit Recharging the main unit s internal battery from an external DC power source requires the use of the DC recharge cable and the inverter power cable Se...

Страница 16: ...cement parts bulbs batteries charging adapters cables etc contact Vector Technical Support toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the lantern there are no user servicea...

Страница 17: ...Power Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 350 Watt 60 Hz 110 120 VAC Inverter Waveform Modi ed Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm...

Страница 18: ...not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents d...

Страница 19: ...19...

Страница 20: ...20 2006 VECTOR PRODUCTS INC FT LAUDERDALE FL 33312 MADE IN CHINA DK080706...

Отзывы: