5.   Charge the unit until the green CHARGED indicator is lit when the charge status button is  

    pressed - DO NOT EXCEED 8 HOURS MAXIMUM.

6.    After charging, disconnect the cables and store them in the cable storage hatch.

7.3   ALTERNATE DC RECHARGE

If the Inverter is removed from the main unit, the DC recharge cable can be directly connected to 

the black power connector that mates with the inverter’s flat power pins. In this way, the inverter 

and inverter power cable can be used away from the main unit and DC recharge can be ac-

complished. Follow the same charging time and monitor the battery charging by using the battery 

status pushbutton and display.

7.4    SIMULTANEOUS DC RECHARGE AND INVERTER OPERATION

Connecting the inverter power cable and the DC recharge cable makes a heavy-duty DC-to-DC 

cable that can simultaneously recharge the main unit and operate the Inverter while it is mounted 

on Power City. Plug one DC plug into Power City accessory outlet and the other DC plug into a 

vehicle accessory outlet.  When using with AC appliances that draws over120 watts, and at the 

same time the Power City’s battery is deeply discharged, this could draw more than the vehicle’s 

accessory outlet fuse can handle and result in a blown fuse. Use this method with caution. Periodi-

cally monitor DC recharge using the battery status pushbutton and indicators.  

8.  

MAINTENANCE/REPLACEMENT PARTS

For  replacement  parts  (bulbs,  batteries,  charging  adapters,  cables,  etc.),  contact  Vector  

Technical Support toll-free 866-584-5504. Except for a fuse in the inverter and a lamp in the 

lantern, there are no user serviceable parts inside Power City. Periodically, the cables and con-

nectors should be inspected for damage, corrosion, dust, and dirt. If surfaces are dirty, they can 

be wiped clean with a cloth moistened with water and a small drop of detergent. Contacts can 

be wiped clean with a dry cloth.

WARNINGS:

 Other than a fuse in the inverter and a lamp in the lantern, there are no user   

    serviceable parts inside. DO NOT operate unit if there is any evidence of damage. The  

    product must be returned to Vector for testing and repair. Replace any damaged cables  

    immediately before further use.

Refer to section 4.6 for inverter fuse replacement. Refer to section 6.4 for lamp replacement.

9.  

BATTERY DISPOSAL

Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be disposed of 

properly. Recycling is required.  Contact your local authority for information. Failure to comply 

with local, state and federal regulations can result in fines, or imprisonment. Sealed lead battery, 

must be recycled or disposed of properly. For more information on recycling this battery, call 

toll-free 877-288-7722.

BATTERY DISPOSAL WARNINGS:

•  Do not dispose of the battery in fire as this may result in an explosion

•  Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to  

  prevent shorting (shorting can result in injury or fire)

•  Do not expose battery to fire or intense heat as it may explode

Содержание Power City DK080706

Страница 1: ...S INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 S W 30TH AVE FT LAUDERDALE FL 33312 TEL 9...

Страница 2: ...erized systems may be damaged if vehicle battery is jumpstarted Before jump starting this type of vehicle read the vehicle s owner s manual to con rm that external starting assistance is advised Exces...

Страница 3: ...4 7 Inverter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor use 11 5 2 Warnings 11 5 3 Tire In ation or products with a valve stem 12 5 4 In ate other articles without valve stem 12...

Страница 4: ...luable when it becomes necessary to locate battery terminals while preparing to jumpstart a dead battery in the dark changing a tire etc Power City is also ideal to power 12 volt DC cordless portable...

Страница 5: ...er hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter with a 120 volt AC standard type plug Operate using 23 ampere rated 12 volt acces...

Страница 6: ...nected to chassis most common 4 Make sure Power City s main unit safety switch is turned off 5 Carefully lift negative black jumper cable wire from storage channel starting at clamp end of cable 6 Squ...

Страница 7: ...the inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The green LED will not be lit under shutdown conditions Inverter shutdown is c...

Страница 8: ...s operated away from the main unit the power source must provide between 11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a batter...

Страница 9: ...age to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrect polarity the fuse will blow If the unit does not function after replacement of the fuse the unit must be r...

Страница 10: ...ece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure fr...

Страница 11: ...volt DC accessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 volt DC compressor is the ultimate compressor for all vehicles trailer tires and recreational in atables Three different sized nozz...

Страница 12: ...very rapidly 5 Insert adaptor e g needle into item to be in ated and in ate to desired pressure 6 Turn on compressor switch in ate to desired pressure or fullness refer to paragraph 5 5 7 Remove adapt...

Страница 13: ...on and during under the hood inspections See Figure 9 If an alternative 12 volt DC source is avail able the lantern can be powered from a standard 12 volt accessory socket The lantern draws 11 watts s...

Страница 14: ...sponsible manner Follow local ordinances for disposal 7 RECHARGING POWER CITY S BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid...

Страница 15: ...in their own cable storage hatch in the main unit Recharging the main unit s internal battery from an external DC power source requires the use of the DC recharge cable and the inverter power cable Se...

Страница 16: ...cement parts bulbs batteries charging adapters cables etc contact Vector Technical Support toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the lantern there are no user servicea...

Страница 17: ...Power Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 350 Watt 60 Hz 110 120 VAC Inverter Waveform Modi ed Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm...

Страница 18: ...not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents d...

Страница 19: ...19...

Страница 20: ...20 2006 VECTOR PRODUCTS INC FT LAUDERDALE FL 33312 MADE IN CHINA DK080706...

Отзывы: