7.1   AC RECHARGE

 

AC recharge requires the use of the supplied AC/DC adapter. The adapter must be powered 

from 120 volt AC, 60 Hz North American standard household AC outlets. The battery status 

display will automatically activate during AC recharge. As recharge progresses, the red LEDs 

will light one by one. Charge the Power City until the battery status display lights the green 

FULL LED. Continue to recharge for one to two hours, and then disconnect the AC Recharger.  

AC  recharge  is  an  automatic  float  and  taper  charge  and  The  AC  Recharger  can  be  left  

connected to the main unit for long periods. See Figure 2 for AC recharge connection to the main 

unit. Refer to Section 7.2 for recharge method.

Make sure that the inverter, compressor and lamp on/off Switches are in off position during AC 

recharging. 

7.2   DC RECHARGE

Power City is supplied with two accessory cables. One cable is a black Inverter power cable with 

an attached thinner lantern extension cord. It is to power the inverter when it is used with another 

accessory outlet in a vehicle or boat. An attached thinner wire is dubbed lantern extension cord” 

and it is used to power the lantern.  The DC recharge cable has red and black wire and it mates 

with the inverter power cable to make a DC to DC cable.  

After recharge, the accessory cables are stored in their own cable storage hatch in the main unit.

Recharging the main unit’s internal battery from an external DC power source requires the use 

of the DC recharge cable and the inverter power cable. (See Figure 12)  The lantern extension 

cord  can be connected to the lantern to simultaneously recharge the main unit and power the 

lantern (not shown). 

FIGURE 12

Make sure safety on/off Switch, inverter, and compressor switches are in the off position during 

DC recharging. 

Unlike the AC recharge method, DC recharge does not automatically activate the battery status 

display. To check the battery status, press the Battery Status Display Push-button. If the jump- starter’s 

battery is fully discharged, it is recommended that the host vehicle or boat’s engine being used for 

recharging be left operating while the unit is being charged using the 12 volt DC/DC method.

WARNING:

 DO NOT recharge main unit for more than 8 hours maximum using 12 volt DC  

    method. Do not charge lantern for more than five hours using the dc recharge method.

1.   Remove both power cables from the cable storage hatch.

2.   Insert the red DC recharge cable’s rectangular connector flat pins into the black rectangu-

    lar connector on the inverter power cable.

3.   Insert  black  DC  plug  on  the  inverter  power  cable  into  a  DC  accessory  socket  on  the  

    main unit.

4.   Plug the red DC plug into an accessory socket in a vehicle, power supply or other 12 volt  

    DC source.

LANTERN 

EXTENSION 

CORD

BARREL CON-

NECTOR

DC RECHARGE 

PLUG

INVERTER 

POWER CABLE

CONNECTOR 

PAIR

DC PLUG

Содержание Power City DK080706

Страница 1: ...S INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 S W 30TH AVE FT LAUDERDALE FL 33312 TEL 9...

Страница 2: ...erized systems may be damaged if vehicle battery is jumpstarted Before jump starting this type of vehicle read the vehicle s owner s manual to con rm that external starting assistance is advised Exces...

Страница 3: ...4 7 Inverter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor use 11 5 2 Warnings 11 5 3 Tire In ation or products with a valve stem 12 5 4 In ate other articles without valve stem 12...

Страница 4: ...luable when it becomes necessary to locate battery terminals while preparing to jumpstart a dead battery in the dark changing a tire etc Power City is also ideal to power 12 volt DC cordless portable...

Страница 5: ...er hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter with a 120 volt AC standard type plug Operate using 23 ampere rated 12 volt acces...

Страница 6: ...nected to chassis most common 4 Make sure Power City s main unit safety switch is turned off 5 Carefully lift negative black jumper cable wire from storage channel starting at clamp end of cable 6 Squ...

Страница 7: ...the inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The green LED will not be lit under shutdown conditions Inverter shutdown is c...

Страница 8: ...s operated away from the main unit the power source must provide between 11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a batter...

Страница 9: ...age to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrect polarity the fuse will blow If the unit does not function after replacement of the fuse the unit must be r...

Страница 10: ...ece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure fr...

Страница 11: ...volt DC accessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 volt DC compressor is the ultimate compressor for all vehicles trailer tires and recreational in atables Three different sized nozz...

Страница 12: ...very rapidly 5 Insert adaptor e g needle into item to be in ated and in ate to desired pressure 6 Turn on compressor switch in ate to desired pressure or fullness refer to paragraph 5 5 7 Remove adapt...

Страница 13: ...on and during under the hood inspections See Figure 9 If an alternative 12 volt DC source is avail able the lantern can be powered from a standard 12 volt accessory socket The lantern draws 11 watts s...

Страница 14: ...sponsible manner Follow local ordinances for disposal 7 RECHARGING POWER CITY S BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid...

Страница 15: ...in their own cable storage hatch in the main unit Recharging the main unit s internal battery from an external DC power source requires the use of the DC recharge cable and the inverter power cable Se...

Страница 16: ...cement parts bulbs batteries charging adapters cables etc contact Vector Technical Support toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the lantern there are no user servicea...

Страница 17: ...Power Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 350 Watt 60 Hz 110 120 VAC Inverter Waveform Modi ed Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm...

Страница 18: ...not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents d...

Страница 19: ...19...

Страница 20: ...20 2006 VECTOR PRODUCTS INC FT LAUDERDALE FL 33312 MADE IN CHINA DK080706...

Отзывы: