4.3.1   PROCEDURE FOR CONNECTING INVERTER TO REMOTE DC SOURCE

Open the cable hatch and remove the Inverter power cable (the one with the lantern extension 

cord) press the inverter cover tab and remove the cover. Ensure that the inverter’s power switch 

is off. Then press the two tabs that lock in the Inverter and release the Inverter and slide it out of 

the mounting. (See Figure 4)

NOTE:

 One of the two flat pins on the bottom of the Inverter is wider than the other pin. 

    Connect the DC recharge cable onto these flat pins. Connect the plug of the DC recharge  

    cable to a 12 volt DC source. 

CAUTION:

    When operating inverter from accessory plug, do not exceed 150 watts for long  

 

    periods of time.

4.3.2   OPERATING TIME

Assuming  a  typical  vehicle  battery  is  the  power  source,  a  minimum  operating  time  of  2  to 

3  hours  can  be  expected.  In  most  instances,  5  to  10  hours  of  operating  time  is  achievable.  

However, Vector recommends that the operator start the vehicle every 2 to 3 hours to recharge 

the battery system. This will guard against any unexpected shutdown of the equipment and will 

ensure that there is always sufficient battery capacity to start the vehicle’s engine. The inverter 

will sound it’s alarm when DC voltage drops to 10.6 volts.

CAUTION:

 Reverse polarity connection will result in damage to the inverter. THIS WILL VOID  

    THE WARRANTY.
If the inverter is connected to the incorrect polarity, the fuse will blow. If the unit does not function 

after replacement of the fuse, the unit must be returned to Vector for repair. Repairs for this type 

of damage are not covered by warranty.

CAUTION:

  Do  not  use  with  positive  ground  electrical  systems  (the  majority  of  modern  

    automobiles, RVs and trucks are negative ground).

4.4    POWERING AN AC LOAD

The power inverter is equipped with a standard AC household-type receptacle and on/off switch. 

Plug the power cord from the equipment you wish to operate into the AC outlet. The green LED 

will light to indicate that the unit is functioning. Make sure the wattage rating of your equipment is 

within 200 watts. If so, turn on your equipment. If an audible alarm sounds, the DC supply voltage 

is too low. If the inverter is connected to the main unit, then the battery needs to be recharged. If 

the inverter is connected to another DC source, then the voltage is too low because of a discharged 

battery or the wiring gauge is not heavy enough.

WARNING  ABOUT  OUTLET  STRIP  USE:  Remove  appliance  plug  from  outlet  strip  or  turn  off       

inverter before working on the AC appliance. Multiple outlet power strips with switches and circuit 

breakers only interrupt power to the “hot” receptacle terminals. The “neutral” terminals remain 

powered with respect to the “ground” terminals. 

LIFT INVERTER 

TO REMOVE

FLAT PINS

COMPRESSOR 

GAUGE

TO 12 VOLT  

DC SOURCE

INVERTER/LANTERN 

POWER CABLE

Содержание Power City DK080706

Страница 1: ...S INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 S W 30TH AVE FT LAUDERDALE FL 33312 TEL 9...

Страница 2: ...erized systems may be damaged if vehicle battery is jumpstarted Before jump starting this type of vehicle read the vehicle s owner s manual to con rm that external starting assistance is advised Exces...

Страница 3: ...4 7 Inverter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor use 11 5 2 Warnings 11 5 3 Tire In ation or products with a valve stem 12 5 4 In ate other articles without valve stem 12...

Страница 4: ...luable when it becomes necessary to locate battery terminals while preparing to jumpstart a dead battery in the dark changing a tire etc Power City is also ideal to power 12 volt DC cordless portable...

Страница 5: ...er hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter with a 120 volt AC standard type plug Operate using 23 ampere rated 12 volt acces...

Страница 6: ...nected to chassis most common 4 Make sure Power City s main unit safety switch is turned off 5 Carefully lift negative black jumper cable wire from storage channel starting at clamp end of cable 6 Squ...

Страница 7: ...the inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The green LED will not be lit under shutdown conditions Inverter shutdown is c...

Страница 8: ...s operated away from the main unit the power source must provide between 11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a batter...

Страница 9: ...age to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrect polarity the fuse will blow If the unit does not function after replacement of the fuse the unit must be r...

Страница 10: ...ece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure fr...

Страница 11: ...volt DC accessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 volt DC compressor is the ultimate compressor for all vehicles trailer tires and recreational in atables Three different sized nozz...

Страница 12: ...very rapidly 5 Insert adaptor e g needle into item to be in ated and in ate to desired pressure 6 Turn on compressor switch in ate to desired pressure or fullness refer to paragraph 5 5 7 Remove adapt...

Страница 13: ...on and during under the hood inspections See Figure 9 If an alternative 12 volt DC source is avail able the lantern can be powered from a standard 12 volt accessory socket The lantern draws 11 watts s...

Страница 14: ...sponsible manner Follow local ordinances for disposal 7 RECHARGING POWER CITY S BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid...

Страница 15: ...in their own cable storage hatch in the main unit Recharging the main unit s internal battery from an external DC power source requires the use of the DC recharge cable and the inverter power cable Se...

Страница 16: ...cement parts bulbs batteries charging adapters cables etc contact Vector Technical Support toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the lantern there are no user servicea...

Страница 17: ...Power Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 350 Watt 60 Hz 110 120 VAC Inverter Waveform Modi ed Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm...

Страница 18: ...not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents d...

Страница 19: ...19...

Страница 20: ...20 2006 VECTOR PRODUCTS INC FT LAUDERDALE FL 33312 MADE IN CHINA DK080706...

Отзывы: