background image

6

1.   TIRE VALVE CONNECTOR

2.   COMPRESSOR HOSE

3.   AC/DC CHARGER

4.   INVERTER POWER CORD,    

 

LANTERN EXTENSION  

 

 

CORD

5.   CABLE & NOZZLES  

 

 

STORAGE COMPARTMENT 

6.   DC RECHARGE POWER  

 

 

CORD

7.   CABLE STORAGE CHANNEL

8.   NEGATIVE JUMPER CABLE

9.  POSITIVE JUMPER CABLE

10. COMPRESSOR HOSE  

 

 

STORAGE CHANNEL

11. RETRACTABLE HANDLE

12. 3 COMPRESSOR HOSE

 

ADAPTERS

6

11

1

5  

7 8 

10

9

12 

1.4   STORAGE LOCATIONS

Figure  3  shows  all  removable  parts  and  their  locations. 

NOTE:

  The  location  of  the  storage  

channels for the jumper cables and compressor hose and nozzle. Two cables are supplied with 

Power City and they are the inverter power cable with attached lantern extension cord and the DC 

recharge cable. They fit inside the cable storage hatch. Three compressor hose adapters (nozzles) 

are also stored in the cable storage hatch.

FIGURE 3

2.  

USING POWER CITY AS A JUMP-START SYSTEM

Read all Warnings, Cautions and Notes carefully before using these instructions. In particular 

read and understand the WARNINGS printed on inside cover.

2.1   JUMP-START PROCEDURE

1.    Turn off ignition and all accessories (radio, a/c, lights, cell phone, etc.). Place vehicle in   

      “park” and set the emergency brake.

2.    Make sure Power City’s safety switch is turned off.

3.    Observe  jumpstarting  negative  or  positive  ground  system,  as  follows:  Negative  ground  

      (negative battery Terminal connected to chassis) - most common.

4.    Make sure Power City’s main unit safety switch is turned off.

5.    Carefully lift negative (black) jumper cable wire from storage channel starting at clamp  

      end of cable.

6.    Squeeze negative (black) clamp handles and slide clamp from holster.

7.     Carefully lift positive (red) jumper cable wire from storage channel starting at clamp end of   

      cable.

8.    Squeeze positive (red) clamp handles and slide clamp from holster.

9.    Connect positive (+) red clamp to vehicle’s positive battery terminal.

10.   Connect  negative  (-)  black  clamp  to  chassis  or  a  solid,  non-moving,  metal  vehicle  

      component or body part - never clamp directly to negative battery terminal or moving part. If  

      audible alarm sounds, DO NOT turn on safety switch reverse polarity of cable connections.

11.  Turn On Power City’s safety switch

12.  Start vehicle (crank engine in 5 - 6 second bursts) If engine won’t start, seek help and go  

      to step 15.

13.  After vehicle starts turn Power City’s safety switch to off position.

14.  Leave engine running.

15.  Remove clamps (disconnect the negative (black) clamp first; followed by the positive (red)  

      clamp and store cables and clamps.

16.  Squeeze negative (black) clamp handles and slide clamp into holster.

17.  Carefully press negative (black) jumper cable wire into storage channel starting at lantern  

      end of cable.

18.  Squeeze positive (red) clamp handles and slide clamp into holster.

19.  Carefully press positive (red) jumper cable wire into storage channel starting at lantern 

      end of cable.

20.  Recharge Power City as soon as possible.

Содержание Power City DK080706

Страница 1: ...S INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 S W 30TH AVE FT LAUDERDALE FL 33312 TEL 9...

Страница 2: ...erized systems may be damaged if vehicle battery is jumpstarted Before jump starting this type of vehicle read the vehicle s owner s manual to con rm that external starting assistance is advised Exces...

Страница 3: ...4 7 Inverter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor use 11 5 2 Warnings 11 5 3 Tire In ation or products with a valve stem 12 5 4 In ate other articles without valve stem 12...

Страница 4: ...luable when it becomes necessary to locate battery terminals while preparing to jumpstart a dead battery in the dark changing a tire etc Power City is also ideal to power 12 volt DC cordless portable...

Страница 5: ...er hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter with a 120 volt AC standard type plug Operate using 23 ampere rated 12 volt acces...

Страница 6: ...nected to chassis most common 4 Make sure Power City s main unit safety switch is turned off 5 Carefully lift negative black jumper cable wire from storage channel starting at clamp end of cable 6 Squ...

Страница 7: ...the inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The green LED will not be lit under shutdown conditions Inverter shutdown is c...

Страница 8: ...s operated away from the main unit the power source must provide between 11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a batter...

Страница 9: ...age to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrect polarity the fuse will blow If the unit does not function after replacement of the fuse the unit must be r...

Страница 10: ...ece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure fr...

Страница 11: ...volt DC accessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 volt DC compressor is the ultimate compressor for all vehicles trailer tires and recreational in atables Three different sized nozz...

Страница 12: ...very rapidly 5 Insert adaptor e g needle into item to be in ated and in ate to desired pressure 6 Turn on compressor switch in ate to desired pressure or fullness refer to paragraph 5 5 7 Remove adapt...

Страница 13: ...on and during under the hood inspections See Figure 9 If an alternative 12 volt DC source is avail able the lantern can be powered from a standard 12 volt accessory socket The lantern draws 11 watts s...

Страница 14: ...sponsible manner Follow local ordinances for disposal 7 RECHARGING POWER CITY S BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid...

Страница 15: ...in their own cable storage hatch in the main unit Recharging the main unit s internal battery from an external DC power source requires the use of the DC recharge cable and the inverter power cable Se...

Страница 16: ...cement parts bulbs batteries charging adapters cables etc contact Vector Technical Support toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the lantern there are no user servicea...

Страница 17: ...Power Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 350 Watt 60 Hz 110 120 VAC Inverter Waveform Modi ed Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm...

Страница 18: ...not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents d...

Страница 19: ...19...

Страница 20: ...20 2006 VECTOR PRODUCTS INC FT LAUDERDALE FL 33312 MADE IN CHINA DK080706...

Отзывы: