LVP615D series user manual
Chapter 6: Setup menu instructions
6.9 PIP / PBP setting
D.
PIP/PBP
Mode=M1
--------------------------------------
D.1 PIP Width
640
D.2 PIP Height
320
D.3 PIP H_Start
16
D.4 PIP V_Start
16
D.5 MAIN Width
1920
D.6 MAIN height
1080
D.7 MAIN H_Start
0
D.8 MAIN V_Start
0
The setup option is used to set LVP615D’s three user defined
PIP/PBP
mode. Operation as below:
When LVP615D’s PIP/PBP status is open (the indicator light on “On/Off” button is lit up), press Setup
button, LVP615D enters “D. PIP/PBP” menu. Then press mode button (M1, M2 or M3) to select a mode
to save parameters, press ↓ to select parameter option needed to adjust. For example “D.1 Main Width”,
rotate
knob
to change parameter, press OK button to save.
(
0
,
0
)
PIP H_start
PIP Width
PIP V_Start
PIP height
Main out image
LVP615D output resolution = 1920×1080
1920
10
80
Pip
out
Main V_start
Main height
Main width
main H_start