![VAT 655 Series Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/vat/655-series/655-series_installation-operating-and-maintenance-instructions_4124026080.webp)
OPERATION
Series 655
80/112
Edition 23.09.2019
979645EA
5.10
Operation under increased temperature
CAUTION
Hot valve
Heated valve may result in minor or moderate injury.
Do not touch valve and heating device during operation. Once heating is switched off
(valve and system) await until the valve is cooled down complete before doing any work.
This valve may be operated in the temperature range mentioned in chapter
«Technical data».
5.11
Behavior In case of compressed air pressure drop
Valve position
before
pressure drop:
Reaction of valve:
Valve closed
Valve remains closed.
Valve open or in any
intermediate position
Sealing ring moves down and blocks the pendulum plate at the current position.
Refer to chapter: «Troubleshooting» for details.