![VAT 655 Series Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/vat/655-series/655-series_installation-operating-and-maintenance-instructions_4124026067.webp)
Series 655
INSTALLATION
979645EA
Edition 23.09.2019
67/112
Command
Service Code
Class ID
Instance ID
Attribute ID
Service
data length
(number of bytes)
Service
data field
Description
EXCEPTION
DETAIL
ALARM
EXCEPTION
DETAIL
WARNING
Get
14
48
1
13 Alarm
14 Warning
15
See below
Table with EXCEPTION DETAIL ALARM resp. EXCEPTION DETAIL WARNING bits.
Data Component
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
PCV Common Exception
Detail Size
0
0
0
0
0
0
1
0
1
PCV Common Exception
Detail Byte #0
0
0
0
0
0
0
0
0
2
PCV Common Exception
Detail Byte #1
0
0
0
0
0
0
0
0
3
PCV Device Exception
Detail Size
0
0
0
0
0
1
0
0
4
PCV Device Exception
Detail Byte #0
0
0
0
0
0
0
0
0
5
PCV Device Exception
Detail Byte #1
0
0
0
0
0
0
0
0
6
PCV Device Exception
Detail Byte #2
0
0
0
0
0
0
0
0
7
PCV Device Exception
Detail Byte #3
0
0
0
0
0
0
0
0
8
Manufacturer Exception
Detail Size
0
0
0
0
0
1
1
0
9
Manufacturer Exception
Detail Byte #0
Warning
Reserved
Reserved
External
isolation
valve
failure
Reserved
PFO not
ready
Compressed
air failure
Learn data
set
invalid
Reserved
10
Manufacturer Exception
Detail Byte #1
Warning
Reserved
Reserved
Reserved
Reserved
Reserved
ADC not
responding
Reserved
Reserved
11
Manufacturer Exception
Detail Byte #2
Warning
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
No sensor
12
Manufacturer Exception
Detail Byte #3
Warning
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
PFO off
Simulation
active
13
Manufacturer Exception
Detail Byte #4
Alarm
Reserved
Reserved
Reserved
Reserved
E40
E22
E21
E20
14
Manufacturer Exception
Detail Byte #5
Alarm
Reserved
Reserved
Reserved
Reserved
Setpoint
invalid
(safe state)
IO data
missing
(safe state)
Setpoint
type invalid
(safe state)
Control
mode
invalid
(safe state)