![VAT 655 Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/vat/655-series/655-series_installation-operating-and-maintenance-instructions_4124026033.webp)
Series 655
INSTALLATION
979645EA
Edition 23.09.2019
33/112
4.4.3.3
Digital inputs
Pin
Function
Description
13
INTERLOCK
CLOSE
This function will close the valve.
•
The input has priority over the remote interface
•
The input can be inverted
•
The input can be switched off
•
The function can be set to function INTERLOCK OPEN
•
INTERLOCK CLOSE has priority over INTERLOCK OPEN
12
INTERLOCK
OPEN
This function will open the valve.
•
The input has priority over the remote interface
•
The input can be inverted
•
The input can be switched off
•
The function can be set to function INTERLOCK CLOSE
•
INTERLOCK CLOSE has priority over INTERLOCK OPEN
14
INPUT
COMMON
Common for all digital inputs
See also «»
4.4.3.4
Digital output
Pin
Function
Signal
type
Description
6
VALVE
CLOSED
Digital
output
This function will indicate that the valve is closed.
•
The output can be inverted
•
The output can be switched off
•
The function can be set to function OPENED or HOLD
5
VALVE
OPENED
Digital
output
This function will indicate that the valve is open.
•
The output can be inverted
•
The output can be switched off
•
The function can be set to function CLOSED or HOLD
7
OUTPUT
COMMON
Digital
common
Common for all digital output. C or – terminal of source with
common