INSTALLATION
Series 655
72/112
Edition 23.09.2019
979645EA
4.10.11
Pressure Controller Object (Class ID 100)
VAT specific attributes
Command
Service Code
Class ID
Instance ID
Attribute ID
Service
data length
(number of bytes)
Service
data field
Description
CONTROLLER MODE
Get
14
100
1
103
1
X
This command returns the device status.
X:
1 = synchronization, 2 = POSITION CONTROL, 3 = CLOSED
4 = OPEN, 5 = PRESSURE CONTROL, 6 = HOLD , 7 = LEARN
12 = power failure, 13 = safety mode
14 = fatal error (read EXCEPTION DETAIL ALARM for details)
ACCESS MODE
Set
16
100
1
107
1
X
Get
14
X:
0
Local (operation via service port)
1
Remote (operation via DeviceNet
®
)
2
Locked (remote, no access from service port)
THROTTLE CYCLE
COUNTER
Get
14
100
1
101
4
X
X:
Data type is unsigned long integer.
A movement from max. throttle position to open back to max. throttle position counts as one
cycle. Partial movements will be added up until equivalent movement is achieved.
ISOLATION CYCLE
COUNTER
Get
14
100
1
106
4
X
X:
Data type is unsigned long integer.
Each closing of the sealing ring counts as one cycle.
HOMING END
CONTROL MODE
Set
16
100
1
112
1
X
Get
14
X:
0
closed
1
open
This command controls / returns the valve position after power up.
POWER FAIL
FUNCTIONALITY
Set
16
100
1
113
1
X
Get
14
X:
0
closed
1
open
This command controls / returns the target valve position in case of a power failure.
Only for versions that have Power Fail Option equipped [612 . . - . . C . - . . . . or
612 . . - . . H . - . . . . or 612 . . - . . U . - . . . . or 612 . . - . . W . - . . . .].