![VAT 655 Series Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/vat/655-series/655-series_installation-operating-and-maintenance-instructions_4124026066.webp)
INSTALLATION
Series 655
66/112
Edition 23.09.2019
979645EA
4.10.8
S-Device Supervisor Object (Class ID 48)
Centralizes application object state definitions and related status information
Command
Service Code
Class ID
Instance ID
Attribute ID
Service
data length
(number of bytes)
Service
data field
Description
DEVICE STATUS
Get
14
48
1
11
1
X
X:
1
self test
2
idle
3
self test exception
4
executing
5
abort
This attribute represents the current state of the device.
Note: EXECUTING must to be selected to enable for all executing commands.
Note: A successfully established Poll-IO connection switches the DEVICE STATUS to
executing.
EXECUTING
(START)
6
48
1
-
3
-
This command changes the DEVICE STATUS to executing state.
Note: If DEVICE STATUS is already in executing state a new EXECUTING results in an
error return.
IDLE
(STOP)
7
48
1
3
-
-
This command changes the DEVICE STATUS to idle state.
EXCEPTION STATUS
Get
14
48
1
12
1
The exception status byte only indicates that alarms or warnings are present.
For details see EXCEPTION DETAIL ALARM resp. EXCEPTION DETAIL WARNING.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
Manufacturer
specific
warning
reserved
reserved
reserved
Manufacturer
specific alarm
reserved
reserved