![VAT 613 Series Скачать руководство пользователя страница 98](http://html1.mh-extra.com/html/vat/613-series/613-series_installation-operating-and-maintenance-instructions_4067198098.webp)
OPERATION
Series 613
98/149
Edition 12.08.2022
984360EC
Gasflow calculation for Learn
Do not apply a different gasflow for learn than determined below. Otherwise
pressure control performance may be insufficient. Required pressure / flow regime
must be known to calculate the most suitable learn gas flow for a specific
application.
Note: The subsequent calculation can be conveniently performed in the
CPA/Navigation/Adaptive Learn > Gas Flow Calculation > Calculate
1.
At first it is necessary to find out about the required control range respectively its conductance
values. Each working point (pressure / flow) must be calculated with one following formulas.
Choose the applicable formula depending on units you are familiar with.
C
WP
required conductance of working point [l/s]
q
WP
gasflow of working point [Pa m3/s]
p
WP
pressure of working point [Pa]
C
WP
required conductance of working point [l/s]
q
WP
gasflow of working point [mbar l/s]
p
WP
pressure of working point [mbar]
C
WP
required conductance of working point [l/s]
q
WP
gasflow of working point [sccm]
p
WP
pressure of working point [Torr]
2.
Out of these calculated conductance values choose the lowest.
C
R
required lower conductance [l/s]
C
WPx
required conductance of working points [l/s]
To make sure that the valve is capable to control the most extreme working point verify
that CR
≥
Cmin of the valve (refer to «Technical data»).
3.
Calculate gasflow for learn. Choose the applicable formula depending on units you are familiar
with.
p
SFS
•
C
min
q
L
=
1100
q
L
gasflow for learn [Pa m
3
/s]
p
SFS
sensor full scale pressure [Pa]
C
min
min. controllable conductance of valve [l/s], (refer to
«Technical data»)
p
SFS
•
C
min
q
L
=
1.1
q
L
gasflow for learn [mbar l/s]
p
SFS
sensor full scale pressure [mbar]
C
min
min. controllable conductance of valve [l/s], (refer to
«Technical data»)
q
L
= 71
•
p
SFS
•
C
min
q
L
gasflow for learn [sccm]
p
SFS
sensor full scale pressure [Torr]
C
min
min. controllable conductance of valve [l/s], (refer to
«Technical data»)
1000
•
q
WP
C
WP
=
p
WP
q
WP
C
WP
=
p
WP
q
WP
C
WP
=
78.7
•
p
WP
C
R
= min(C
WP1,
C
WP2, . . . ,
C
WPn
)