Series 613
TROUBLE SHOOTING
984360EC
Edition 12.08.2022
123/149
7.2.3
Error Number
Error numbers are three-digit decimal numbers (xyz) whereas:
x = component
y = mode
z = error type
1 = All Motor Units
2 = Motor Unit 1
3 = Motor Unit 2
4 = Motor Unit 3
8 = Other
0 = Homing
2 = Operation Mode
8 = Other
0 = Position Error
1)
1 = Not running: No communication with component x
2 = Error State: component x is running but in Status Error
8 = Other
7.2.4
Error Code
1)
Mechanical movement problem:
•
Check for differential pressure
•
Remove foreign object in movement area
•
Eliminate tight movement
•
Repair mechanical failure
Code Description
Solution
1
No valve connected
Connect valve controller to the valve
2
Nonvolatile memory failure
Replace valve controller
3
Analog digital converter of sensor input failure
Replace valve controller
4
Initialization of motion controller failed
Wrong motion controller firmware version
Update motion
controller firmware
5
Encoder index pulse not found
•
1)
•
Encoder failure
•
O-ring sticking
6
Initialization of interface module failed
•
Fieldbus: Valve firmware does not support interface type
Update valve firmware
•
Wrong interface firmware version
Update interface firmware
7
Initialization of external drive EEProm failed
Check cables
10
Closing position can’t be reached
1)
11
Homing position can’t be reached
•
1)
•
Plate not mounted
12
Motion controller: Internal voltage error
Check power supply
13
Motion controller: Internal error temperature
Check for a heat accumulation
14
Motion controller: Unexpected behavior
Contact vat support
•
Axis inverted
•
Encoder not connected
•
Break not released
15
Motion controller: Target position can’t be
reached
•
1)
•
Current Settings
16
Motion controller: Position minimal conductance
cannot be reached
•
1)
•
Check Plate and Seal ring
•
Check Parameter “Isolation Position Enter [r]”
17
Motion controller: Position to push back the
Differential Plate cannot be reached
•
1)
•
Check Different Plate
•
Check Parameter “Differential Plate Push Back Position [r]”
18
Motion controller: Minimal isolation position
cannot be reached
•
1)
•
Check Plate and Seal ring
•
Check Parameter “Isolation Position [r]”
20
Break slippery detected
Replace actuator