OPERATION
Series 613
118/149
Edition 12.08.2022
984360EC
6.4
Position Control
6.4.1
Parameter
Location: CPA/Navigation/Parameters: Position Control
Parameter
Description
Actual Position
Position of the valve plate
Range depends on Position Scaling setting (on Interface and CPA)
Target Position
Desired position of the valve plate
Range depends on Position Scaling setting (on Interface and CPA)
Position Control Speed Speed of the valve in Control Mode Position
0.001 .. 1.0 (Full speed)
Ramp
See below
6.4.2
Position Ramp
.
6.4.2.1
Configuration
Location: CPA/Navigation/Parameters: Position Control.Ramp
Parameter
Description
Enable
Activate / Deactivate position ramp
Mode
0:Use Ramp Time
1:Use Ramp Slope
See description below
Time
Target reach time in seconds (Used if Mode = 0)
Slope
Limit the rate of position change per second (Used if Mode = 1)
Type
0:Linear
1:Logarithmic
2:Exponential
Ramp
Target Position
Valve Position