DIP-1C USER’S GUIDE 

Section C-32 

DIP-1C 

(POS 12) 

System Parameters 

SYSTM

 

This parameter indicates that the DIP-1C is in system parameter mode. 

Communication Filter 

FILTR

 

This parameter is reserved for the manufacturer’s technical support 
personnel. 

www.monitrol.com

Содержание DIP-1C

Страница 1: ...th potentiometer feedback Varifan 5 5 DIP 1C OPENING CLOSING MANUAL TEMP TE M P MINIMU M SUMMER POS WINTER POS ACTUAL POS MANUAL OVERRIDE VARIABLE POS STAGE POS OUT TEMP CALIB LOW LIMIT INLET PRECI SION ALARM CODE 11 12 1 2 3 4 5 7 6 10 9 8 UNIT 2 VAR P O S STG POS VARIABLE POS STAGE POS 73 USER S GUIDE INSTALLATION GUIDE INDEX WARRANTY WIRING DIAGRAM www monitrol com ...

Страница 2: ...pment may damage this equipment For added security against line voltage surges it is recommended that surge and noise suppression devices be installed at the electrical distribution panel Use of shielded cable for probes is recommended for protection against lightning These devices are available from most electrical supply distributors RECOMMENDATIONS The manufacturer recommends that all installat...

Страница 3: ...DIP 1C WIRING DIAGRAM DIP 1C Section A 3 WIRING DIAGRAM DIP 1C SECTION A www monitrol com ...

Страница 4: ...ND MGCB CTL1 A1 C1 B1 ACT L1 FEEDBACK POTENTIOMETER CLOSE OPEN COM INLET INLET 115 230 VAC C L1 L2 N 8 8VAC MGCB GND PLS MODULES 8 8VAC MGCB GND PLS MODULES LINE VOLTAGE SELECTOR 230V SEE NOTES ON PAGE A 6 WIRING DIAGRAM WARNING SET LINE VOLTAGE TO CORRECT VALUE BEFORE ATTEMPTING TO OPERATE THE MODULE ECS xC CONTROL ECS xC CONTROL WIRING DIAGRAM DIP 1C 115 230VAC INLET 8 www monitrol com ...

Страница 5: ...A1 C1 B1 ACT L1 FEEDBACK POTENTIOMETER INLET INLET 24 VDC C ECS xC CONTROL 8 8VAC MGCB GND PLS MODULES ECS xC CONTROL 8 8VAC MGCB GND PLS MODULES LINE VOLTAGE SELECTOR 230V TRANSFORMER 24V GND 24V SEE NOTES ON PAGE A 6 EXTERNAL 24 VOLTS POWER SUPPLY WIRING DIAGRAM WIRING DIAGRAM DIP 1C 24VDC INLET WARNING SET LINE VOLTAGE TO CORRECT VALUE BEFORE ATTEMPTING TO OPERATE THE MODULE 8 www monitrol com ...

Страница 6: ...RES AT A 90 DEGREE ANGLE RELAYS 10A 240VAC RESISTIVE MOTOR 1HP 240VAC 1 2HP 120VAC AT EACH OUTPUT MAXIMUM 2 WIRES OF SAME SIZE PER BLACK TERMINAL NO BIGGER THAN AWG 12 NO SMALLER THAN AWG 22 1 WIRE ONLY PER GREEN TERMINAL USE WIRE CONNECTOR IF YOU WANT TO CONNECT MORE THAN 1 WIRE NO BIGGER THAN AWG 12 NO SMALLER THAN AWG 28 CHECK INSTALLATION GUIDE FOR ALARM WIRING USE SHIELD FOR SHIELDING PURPOSE...

Страница 7: ...DIP 1C INSTALLATION DIP 1C Section B 7 INSTALLATION DIP 1C SECTION B www monitrol com ...

Страница 8: ... for damage Should the contents appear to be damaged contact your local distributor to return the equipment The package should contain the following standard items 1 DIP 1C Module 4 Brackets 4 Screws 1 Installation User s Guide Mounting Hardware Required This is the list of the mounting hardware needed which is not included with the product Shielded two wire twisted pair cable AWG 22 used for comm...

Страница 9: ...r high voltage equipment power supply or transformer Electrical Cables All electrical cables must be installed according to local wiring codes All cable shields must be connected to the DIP 1C power ground only except for the cable connected to the optional PC interface and to the ventilation controllers The shield is needed to protect the DIP 1C and the modules against any electromagnetic interfe...

Страница 10: ...ted in a location that will allow the cover to be completely opened right up against the wall Fasten the four brackets to the four mounting holes on the back of the enclosure using the four screws provided with the brackets Then mount the enclosure on the wall by inserting screws through the brackets adjustment slots into the wall Make sure to position the enclosure so that all wires extend out of...

Страница 11: ...e power source 2 if source 1 is disabled The backup relay should be selected to ensure it is able to support the required power load FIGURE NO 2 Typical Power Backup Wiring 8 PIN RELAY DPDT OMRON model MK2EP UA AC120 3 4 5 6 2 1 8 7 NO 2 NO 1 NC 1 NC 2 COM 2 COM 1 L2 GND L1 3 4 5 6 2 1 8 7 L2 L1 GND source 1 DISTRIBUTION PANEL L2 L1 N LINE 230 VAC source 2 DISTRIBUTION PANEL LINE 230 VAC www monit...

Страница 12: ...iometer problem power loss or other malfunctions It may be connected to an alarm system or directly to a siren and or auto dialer The relay will activate 6 8 seconds after an alarm is triggered FIGURE NO 3 Typical Alarm Connection Wiring ALARM SYSTEM AUTO DIALER GND MGCB GND MGCB CTL2 ALARM 30V 1A MAX X1340 DIP 1C C1 B1 A1 ACT CTL1 www monitrol com ...

Страница 13: ...p the cover C Insert the configuration chip MMX into the socket of the main board D Switch on the power source The display on the front panel should indicate dNLD for approximately 15 seconds If dNLD is not displayed try one more time If dNLD is still not displayed remove and replace the configuration chip MMX E When the downloading procedure is complete remove the configuration chip MMX and place...

Страница 14: ...ation Here s the procedure to upload a configuration A Make sure that the DIP 1C is powered up B Remove the faceplate screws and lift up the cover C Place the MMX chip into the socket of the main board At this moment the MMX Detected parameter will appear D Adjust the MMX Detected parameter to upLD and press the SET CLR button The display on the front panel should indicate upLD for approximately 1...

Страница 15: ... connected with DIP 1C with a short description of their function Computer interface NET IN2 Communication Module Module inserted into the DIP 1C to communicate with the computer interface RF IN Communication Module Module inserted into the DIP 1C for a wireless communication with the computer interface www monitrol com ...

Страница 16: ...30VDC Delay before activation Between 6 and 8 seconds OUTPUT RELAYS Maximum Current 1HP 240VAC 1 2HP 120VAC 10A 240VAC Caution Notice These relays are rated by UL and CSA at 1HP 240VAC 1 2HP 120VAC However it is recommended not to use more than 1 2HP 240VAC 1 4HP 120VAC per relay COMMUNICATIONS PORT MGCB Maximum wire length 19200 bps 6 5 feet 2 m Recommended wire 2 strands twisted pair low capacit...

Страница 17: ...ing SYMPTOM CAUSE REMEDY Display is blank DIP 1C is not powered Flat cable between the main and top boards of the DIP 1C is disconnected Make sure the control is powered Make sure the fuse is correct Make sure the flat cable is connected www monitrol com ...

Страница 18: ...DIP 1C USER S GUIDE Section C 18 DIP 1C USER S GUIDE DIP 1C SECTION C www monitrol com ...

Страница 19: ... 5 DIP 1C OPENING CLOSING MANUAL TEMP TE M P MINIMU M SUMMER POS WINTER POS ACTUAL POS MANUAL OVERRIDE VARIABLE POS STAGE POS OUT TEMP CALIB LOW LIMIT INLET PRECI SION ALARM CODE 11 12 1 2 3 4 5 7 6 10 9 8 UNIT 2 VAR P O S STG POS VARIABLE POS STAGE POS 73 Module Description 5 1 3 4 6 2 www monitrol com ...

Страница 20: ... with the value setting buttons and 3 Parameter Dial This button is used to select parameters or parameter groups 4 Value Setting Button This button is used to increase or decrease the value on the LED window Turn it clockwise to increase the value Turn it counter clockwise to decrease the value 5 F2 Button This button is used to access to secondary function of a parameter group appears in green a...

Страница 21: ...Qty Outputs Qty Inlet 1 Alarm 1 Equipment Item Description Qty DIP 1C Digital Inlet Positioner 1 Configuration Versions Version Date Min Proc Version Modification V0 05 05 2011 5 New V1 12 08 2014 5 Correction on the stage 8 visibility for the unit 2 www monitrol com ...

Страница 22: ...rol an inlet according to the information received from one or two controllers The inlet will open progressively according to the ventilation level Some position can be influenced by the outside temperature When the inlet s feedback potentiometer is defective an alarm will occur www monitrol com ...

Страница 23: ...1 Variable 1 Start Position parameter This parameter is adjusted in 0 1 increments from 58 0 F to 140 0 F 50 0 C to 60 0 C Summer Minimum Position POS 2 These parameters will only appear if the outside temperature is used on at least one of the units connected to the DIP 1C Summer Minimum Position This parameter is used to adjust the minimum opening position when the Outside Temperature is equal t...

Страница 24: ...meter is adjusted in 1 increments from 0 to 100 Variable 1 End Position 1 END This parameter is used to establish the position the inlet will take when variable 1 of unit 1 runs at its maximum speed This parameter is adjusted in 1 increments from 0 to 100 Variable 2 Start Position 2 STR This parameter is used to establish the position the inlet will take when variable 2 of unit 1 runs at its minim...

Страница 25: ...m 0 to 100 Stage 5 Position 5 POS This parameter is used to establish the position the inlet will take when stage 5 of unit 1 is activated This parameter is adjusted in 1 increments from 0 to 100 Stage 6 Position 6 POS This parameter is used to establish the position the inlet will take when stage 6 of unit 1 is activated This parameter is adjusted in 1 increments from 0 to 100 Stage 7 Position 7 ...

Страница 26: ...Position 1 END This parameter is used to establish the position the inlet will take when variable 1 of unit 2 runs at its maximum speed This parameter is adjusted in 1 increments from 0 to 100 Variable 2 Start Position 2 STR This parameter is used to establish the position the inlet will take when variable 2 of unit 2 runs at its minimum speed When variable 2 of unit 2 runs above its minimum speed...

Страница 27: ...sition 6 POS This parameter is used to establish the position the inlet will take when stage 6 of unit 2 is activated This parameter is adjusted in 1 increments from 0 to 100 Stage 7 Position 7 POS This parameter is used to establish the position the inlet will take when stage 7 of unit 2 is activated This parameter is adjusted in 1 increments from 0 to 100 Stage 8 Position 8 POS This parameter is...

Страница 28: ... the current parameter At this point the LED display will change to SAVED if the value was correctly saved or ERR if the potentiometer reading is not valid In the last case calibration must be performed once the situation is corrected Inlet Precision POS 9 Inlet Precision This parameter is used to adjust the precision of the inlet If the inlet moves too often increase this setting When this is don...

Страница 29: ...ommunication Problem 3 Units 1 2 Not Using Same Temperature Unit 101 The module has reset 10 times and each reset was less than 15 minutes apart from the last one 102 If this alarm code appears contact your distributor 103 If this alarm code appears contact your distributor Manual Override POS 11 Manual Override This parameter is used manually operate the inlet without regard to the calculated dem...

Страница 30: ...ition Winter NOStW This parameter is used to set the position the inlet will take when no ventilation stages are activated and the Outside Temperature is equal to or below Winter Temp When the Outside Temperature is lower than Summer Temp but greater than Winter Temp the position the inlet will take when no ventilation stages are activated will modulate according to this setting and No Stage Posit...

Страница 31: ...nce again or move the parameter dial to end parameter modification This parameter can be adjusted to any value from 0 to 32767 RF Address rF Ad This parameter displays the number address associated to the RF IN card inserted in the controller A unique number is given to each RF IN card of the WiFarm network There is a unique RF Address associated to each RF IN card The RF Address also appears on t...

Страница 32: ...32 DIP 1C POS 12 System Parameters SYSTM This parameter indicates that the DIP 1C is in system parameter mode Communication Filter FILTR This parameter is reserved for the manufacturer s technical support personnel www monitrol com ...

Страница 33: ...to 100 F2 Temp Summer Temp 59 0 F 15 0 C 58 0 to 140 0 F 50 0 to 60 0 C POS 3 UNIT 1 VARIABLE POSITION 1 Str Variable 1 Start Position Adjust at Summer and Winter Minimum Position 0 to 100 F2 1 End Variable 1 End Position 15 0 to 100 F2 2 Str Variable 2 Start Position 35 0 to 100 F2 2 End Variable 2 End Position 45 0 to 100 POS 4 UNIT 1 STAGE POSITION 3 POS Stage 3 Position 70 0 to 100 F2 4 POS St...

Страница 34: ...OS Stage 7 Position 100 0 to 100 F2 8 POS Stage 8 Position 100 0 to 100 POS 7 OUTSIDE TEMPERATURE Outside Temperature 58 0 to 140 0 F 50 0 to 60 0 C POS 8 INLET CALIBRATION Inlet Set Low Limit F2 HI Inlet Set High Limit POS 9 INLET PRECISION Inlet Precision 1 1 to 20 F2 RUn T Inlet Max Run Time OFF 1 to 9 OFF POS 10 ALARM Alarm Code POS 11 MANUAL OVERRIDE Manual Override AUTO AUTO HOLD CLOSE 0 to ...

Страница 35: ...ition Winter 0 0 to 100 POS 8 AlOPT Inlet Alarm Option ON ON OFF POS 9 LANG Display Language Eng Eng Fra POS 10 rF CH RF Channel OFF OFF 1 to 16 F2 Rf NT RF Network 0 0 to 32767 F2 rf Ad RF Address 0 to 32767 F2 U Id Unit ID 1 1 to 250 F2 tPDIS Tech Param Display 1 OFF 1 to 25 F2 tPRES Tech Param Result POS 11 CONF Configuration Version F2 PROC Processor Version POS 12 SYSTM System Parameters F2 F...

Страница 36: ...e Switches Table Switches Default Settings SLIDE SWITCHES SW1 Parameters Locked OFF ON OFF SW2 System Parameters OFF ON OFF DIP SWITCHES DIPSW1 Future Use DIPSW2 Unit Connected OFF 1 Unit OFF 1 Unit ON 2 Units DIPSW3 Future Use DIPSW4 Future Use www monitrol com ...

Страница 37: ...DIP 1C INDEX WARRANTY DIP 1C Section D 37 INDEX WARRANTY DIP 1C SECTION D www monitrol com ...

Страница 38: ...nnection Procedure 11 Detailed Wiring Diagrams 11 Typical Power Backup Wiring 11 Typical Alarm Connection Wiring 12 Powering Up Procedure 13 Verify all Connections 13 Hermetically Close the DIP 1C 13 Put the power on 13 Secure the front panel with a lock 13 Downloading the Configuration 13 Uploading the Configuration 14 DIP 1C Compatible Modules 15 Specifications 16 Troubleshooting 17 TABLE OF FIG...

Страница 39: ...Unit 2 Variable Position POS 5 26 Unit 2 Stage Position POS 6 27 Outside Temperature POS 7 27 Inlet Calibration POS 8 28 Inlet Precision POS 9 28 Alarm Code POS 10 29 Manual Override POS 11 29 Actual Position POS 12 29 System Mode Settings 30 POS 7 30 POS 8 30 POS 9 30 POS 10 31 POS 11 31 POS 12 32 Parameter Table 33 User Settings DIP 1C Accessible when SW2 is set to OFF 33 System Settings DIP 1C ...

Страница 40: ...s of God flood fire hail or any other natural disaster Any unauthorized work modification or repair on this product automatically voids the warranty and disclaims the manufacturer from all responsibility The manufacturer assumes only those obligations set forth herein excluding all other warranties or obligations This warranty stipulates that in all cases the manufacturer shall be liable only for ...

Страница 41: ...www monitrol com ...

Страница 42: ...DIP 1C_EN VER 1 1 August 12 2014 www monitrol com ...

Отзывы: