The Load Demand Feature can be turned OFF by setting
Selector Switch 2
to the OFF position.
This will cause the inverter to remain fully ON, producing 120 Volts AC, whenever the inverter
switch is ON and regardless of AC load. It is desirable to do this when the device being powered
draws less than 5 watts. An example of such a device is a plastic pipe fusion machine which
draws less than 5 watts during the ‘coupling cooling time’. With the Load Demand Feature turned
OFF and operating no AC load the inverter consumes approximately 1.8 amps of 12 volt DC
power.
1.5.3 Automatic Transfer Switch:
The Transfer Switch is a standard feature provided on all IQC models. The Transfer Switch
automatically allows input power, from an external AC power source such as shore power or a
generator, to pass through the inverter output circuit and be used to operate inverter loads.
1.5.4 Automatic Power Management:
The optional Automatic Power Management (APM) Panel, part number D07934, may be used
with IQC Models only. The APM Panel allows the operator to set the maximum AC amps (10
amps, 15 amps, 20 amps or 30 amps) the battery charger may draw from shore power input AC1.
The APM Panel is useful in preventing nuisance tripping of the shore power circuit breaker in
motor home or similar applications, where the size of the shore power circuit breaker varies from
campground to campground and occasionally be rated less than 30 amps. If the AMP Panel is
not used the default setting is 30 amps.
1.5.5 Inverter Mode and Charger Mode
The following applies only to IQC Models. IQ Models do not have charger mode.
The IQC is in ‘Inverter Mode’ when it is functioning as an inverter. The unit is in ‘Charger Mode’
when it is functioning as a battery charger.
For all IQC models, the factor that determines whether the unit is in ‘Inverter Mode’ or ‘Battery
Charger Mode’ is the presence or absence of ‘in-tolerance’ AC input power. Whenever ‘in-
tolerance’ AC input power becomes available the IQC automatically switches from inverter mode
to charger mode.
1.6 Important Safety Instructions
This manual contains important safety and operating instructions for the Vanner Power Group “IQ Series”
Power Inverter and Inverter/Charger System as prescribed by Underwriters Laboratory (UL). The IQ
Series Inverter and Inverter/Charger Family is listed as compliant with UL 458 (only if the UL/CUL symbol
is on the front of the unit), Power Converters/Inverters and Power Converter/Inverter Systems for Land
Vehicles (12 and 24 volt models only), and UL 1741 Power Conditioning Units for use in Residential
Photovoltaic Power Systems. The Vanner Power Group “IQ Series” also is listed to the Canadian National
Standard CSA – C22.2 No. 107.1 – 1951.
SAVE THESE INSTRUCTIONS
WARNING
This equipment employs components that tend to produce arcs and sparks. To prevent
fire or explosion, DO NOT install in confined areas or compartments that contain batteries
or flammable materials.
Содержание IQ12-2600
Страница 1: ...VANNER POWER GROUP VANNER POWER GROUP IQ SERIES IQ SERIES IQ SERIES OWNERS MANUAL 1...
Страница 2: ...VANNER POWER GROUP VANNER POWER GROUP IQ SERIES IQ SERIES 2 IQ SERIES OWNERS MANUAL...
Страница 43: ...VANNER POWER GROUP VANNER POWER GROUP IQ SERIES IQ SERIES IQ SERIES OWNERS MANUAL 43...
Страница 44: ...VANNER POWER GROUP VANNER POWER GROUP IQ SERIES IQ SERIES 44 IQ SERIES OWNERS MANUAL...