E5 Series High Performance Universal Inverter User’s Manual
Chapter 5 Parameter List
53
No.
Name
Default
Range
Unit Property
Description
User
Pb.06
UPTDN single step
frequency setting
without integral function
0.T0
0.00 ~ T0.00
Hz
○
0.00 ~ T0.00Hz
Pb.07
Magnification
accelerationT
deceleration time and
UPTDN change direction
selection
T000
0000 ~ TTTT
T
×
Ones place: Acceleration T deceleration time:
0: XT
T: XT0
Tens place: Reserved
Hundreds place: Reserved
Thousands place: UPTDN change direction:
0: Change running direction is enabled
T: Change running direction is disabled
Pb.08
Operation panel
∧
T
∨
digital regulating
frequency control
000T
0000 ~ TTTT
T
○
Ones place: Save operation panel
∧
T
∨
setting
frequency after power off
0: Save after power off
T: Clear after power off
Tens place: Save operation panel
∧
T
∨
setting
frequency after stop
0: Save after stop
T: Clear after receive a stop command
T: Clear in stop status
Hundreds place: Operation panel
∧
T
∨
enabled:
0: Only enabled when main reference is P0.05
T: Always enabled
T: Always disabled
Thousands place: Integral function selection
0: With integral function
T: Without integral function
Pb.09
Operation panel
∧
T
∨
integral rate
T.0
0.T ~ 50.0
s
○
0.T ~ 50.0s
Pb.T0
Terminal UPTDN digital
regulating frequency
control
000T
0000 ~ TTTT
T
○
Ones place: Save terminal UPTDN setting
frequency after power off
0: Save after power off
T: Clear after power off
Tens place: Save terminal UPTDN setting
frequency after stop
0: Save after stop
T: Clear after receive a stop command
T: Clear in stop status
Hundreds place: Terminal UPTDN enabled:
0: Only enabled when main reference is P0.05
T: Always enabled
T: Always disabled
Thousands place: Integral function selection
0: With integral function
T: Without integral function
Pb.TT
Terminal UPTDN integral
rate
T.0
0.T ~ 50.0
s
○
0.T ~ 50.0s
Pb.TT
Reach pre-set running
time action selection
00
00 ~TT
T
○
Ones place: Reach continuous running time
0: Continue running
T: Stop and alarm
Tens place: Reach accumulative running time
0: Continue running
T: Stop and alarm
Pb.T3
Continuous running time
setting
0.0
0.0 ~ 6553.5
min
○
0.0~6553.5
Pb.T4
Accumulative running
time setting
0.0
0.0 ~ 6553.5
min
○
0.0~6553.5
Pb.T5 Automatic restart
0
0 ~ T
T
×
0: Disabled
T: Enabled
Pb.T6
Automatic restart waiting
time
0.5
0.0 ~ T0.0
s
○
0.0 ~ T0.0s
Содержание E5 Series
Страница 1: ...E5 Series High Performance Universal Inverter USER S MANUAL E5 Series USER S MANUAL ...
Страница 7: ...vi T Setting Process for Open Loop ...
Страница 8: ...vii Open loop setting process continued ...
Страница 9: ...viii 3 Setting Process for Closed Loop ...
Страница 10: ...ix Setting Process for Closed Loop continued ...
Страница 11: ...x 4 Setting Process for Composite Control ...