![Valor L1 Series Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/valor/l1-series/l1-series_installation-and-owners-manual_851548047.webp)
47
QUALIFIED
INSTALLER
Installation
WARNING
CHOKING HAZARD!
Ensure that the fi replace
area is clear of fi reglass particles as these could
be ingested by small children. Vacuum area after
installation.
!
Installed glass plate
2. Install the glass plate on the platform, the textured
side underneath and the smooth side on top. The
plate is fl ush with the edge of the burner. Like for the
steel platform underneath, push the glass platform
as far back as possible to maximize the air gap
behind the burner.
3. Fill a small container with approximately 3 cups
(750 ml) of fi reglass.
4. Carefully spread the fi reglass on the surface of
burner patting it gently with your hand to form a
single layer to the approximate level of the top edge
of the fl ange around the burner. Do not pour too
much to avoid blocking the burner ports.
5. Some fi reglass may be added on the platform to
cover the edge of the burner and in the space in
front and behind the pilot shield.
NOTE:
Ensure the area
within
the pilot shield is
clear of fi reglass.
Pilot shield
Содержание L1 Series
Страница 70: ...70 OWNER S INFORMATION ...