41
QUALIFIED
INSTALLER
X
3-3/4”
(95 mm)
Gas line
access hole
2-1/2” (64 mm)
diam.
4”
(102 mm)
Front
of the
appliance
Installation
5. Tighten cable clamp on outside of fi replace casing
and secure and excess wire to framing.
6. Mount receptacle into electrical box.
7. Mount steel cover to electrical box and plug in the
accessory cable.
Set-up Gas Supply
The gas supply inlet con-
nection is a 3/8” NPT male
connector located on the left
hand side of the fi rebox.
The unit is supplied with a stainless steel fl ex line to
allow the appliance to be disconnected for service. An
individual shut-off valve (not supplied) is required on
the supply line ahead of the fl ex connector.
Use only new black iron or steel pipes or copper tubing
if acceptable—check local codes. Note that in USA,
copper tubing must be internally tinned for protection
against sulfur compounds.
Unions in gas lines should be of ground joint type.
The gas supply line must be sized and installed to
provide a supply of gas suffi cient to meet the maximum
demand of the appliance without undue loss of pressure.
Sealant used must be resistant to the action of all gas
constituents including LP gas. Sealant should be ap-
plied lightly to male threads to ensure excess sealant
does not enter gas lines.
Left side view