![Valor L1 Series Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/valor/l1-series/l1-series_installation-and-owners-manual_851548036.webp)
36
QUALIFIED
INSTALLER
Only qualifi ed licensed or trained personnel
should install this appliance.
Installer—READ THIS FIRST
1. YOU NEED TO KNOW FROM THE
HOMEOWNER:
- Will the optional LDK Duct Kit be used;
- The height of the unit and hearth if used;
- The thickness and type of the wall fi nish
around the fi rebox opening;
- What accessories (trim, decorative lighting,
etc.) will be installed with this fi replace;
- The venting confi guration.
2. Unpack the appliance, removing all items packed
inside and around the appliance.
3. Check that you have everything, using the Pack
Content sheet. Also, check that you have:
◊ a fuel bed (packed separately)
◊ a set of liners (packed separately)
◊ LDK HeatShift kit if used.
4. Carefully read the Installer’s Checklist included with
the fi replace for the installation sequence.
Installation Planning
1/2” (13mm) thick
non-combustible
cement board
Gypsum board
up to perimeter
of cement board
Min.
9-1/4”
(235 mm)
Min.
44-1/2”
(1130 mm)
Min.
20-1/2”
(521 mm)
14-3/4”
(375 mm)
Board flush with
bottom of heater;
add extra if
overlapping
framing.
40”
(1016 mm)
Min. 48”
(1219 mm)
1/4”
(235 mm)
Possible scr
ew loc
(in the designat
ed
ar
d flush with bo
of heat
er; add ex
tra
overlapping fr
aming
Wider trim (1550)
can adjust up to 1”
forward of surface
of cement board
Narrow trim (1575)
can adjust up to
5/8” forward of
surface of cement
board
Plan Wall Finish
Non-Combustible Materials Specifi cations
Material which will not ignite and burn. Such materials
are those consisting entirely of steel, iron, brick, tile,
concrete, slate, glass or plasters, or any combination
thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 °C shall be considered
non-combustible materials.
Combustible Materials Specifi cations
Materials made of or surfaced with wood, compressed
paper, plant fi bers, plastics, or other material that
can ignite and burn, whether fl ame proofed or not,
or plastered or unplastered shall be considered
combustible materials.
Non-combustible cement board
The L1 Linear fi replace requires a 1/2” (13 mm) thick
non-combustible cement board to be used as a wall
surface immediately surrounding the unit on each
side—see diagram for minimum coverage.
Minimum cement