QUALIFIED
INSTALLER
Fold fl at
standoff s
Standoff s installed
Standoff
Remove top outlet (6 screws)
Remove heat shield (3 screws)
Fit Standoff s
The standoff s are supplied fl at on
the fi rebox sides and fi xed at one
end. Swivel up the fl at standoff s,
bend them as shown and fi x the
loose end to the top of the fi rebox.
Remove Heat Shield
Remove the heat shield from the top of the appliance
case (3 screws). If using a rear outlet, keep the shield
to reinstall after converting the top to rear outlet—see
next subsection. If using the top outlet or the LDK
HeatShift Duct Kit, discard the shield.
Swivel the outlet so
that it is oriented
towards the rear and
reinstall to heater
(6 screws)
Reinstall heat
shield to top of
appliance
(3 screws)
Rear outlet with required heat shield
Convert from Top to Rear Outlet
(if required)
This unit is supplied with a top vent outlet which can
be fi eld-converted to a rear vent outlet.
Please note that the rear outlet requires the instal-
lation of the heat shield on top of the heater case
as indicated.
1. Remove the top outlet collar (6 screws).
2. Swivel the collar and install as a rear outlet (6 screws).
3. Reinstall the heat shield to the top of the appliance
case (3 screws).
Fit optional LDK HeatShift Duct Kit’s
take-off collars to appliance
(if used)
See installation instructions packed with the LDK kits
for details.