Page 42
Install: Install by following the dissemble steps in reverse order. Attentions shall be paid to the following
issues. During installing IBT belt, put the check point of the belt on the back for installation. After
replacement, enter diagnosis mode and press the "initialize HFSI counter" to reset the HFSI counter.
See P46-47 "Chain Link: 954-820" for details.
8: Replace developer or developer unit
Note: Before replacing the developer or the developer unit, please pull the toner cartridge and waste toner box out,
remove IBT belt cleaning component and IBT component.
When removing the photosensitive drum, to prevent light fatigue, cover the photosensitive drum with black plastic film.
Do not touch the surface of the photosensitive drum with your hands.
Do not touch the surface of the IBT belt with your hands.
8-7-17
1. Remove the screw; 2. Remove the handle.
8-7-18
Remove the driving roller.
8-7-19
Remove the transfer belt.
8-7-20
Get a new transfer belt for replacement. Make sure the
direction is correct.