55
Maintenance
The complete system should be tested at regular intervals. We suggest testing
it once every fortnight or at least once per month.
Replacement batteries (when required) are available by calling 1800 050 333.
Real Time Clock battery
Your Valet Digital is equipped with a real time clock for logging alarm events
and billing information. The battery for the Real Time Clock is located in the
Main Control Unit, replacing or removing this battery will result incorrect event
logging and billing. Please DO NOT attempt to remove/replace this battery.
Real-Time Clock Battery Specifications
Battery Type
CR2025 Lithium
Capacity
160mAH
Voltage
3V
Main Control Unit Backup Battery
The backup battery is used for providing normal alarm operation during times
when the normal AC mains power is unavailable (such as during a blackout).
The backup battery automatically charges when the Main Control Unit is
connected to the AC adapter. The system has a self-test function to test the
backup battery; it will report a low backup battery on disarm, by beeping 10
times and will also notify the user through the event logging through the
monitoring system.
Manual Battery Test:
Disconnect the Power Supply and ensure the system
will arm and disarm from back up battery power only. If the system failed the
test, then reconnect the power supply and allow it to charge for three hours
before performing another test. Failing the test again will confirm that the
battery needs to be replaced.
Main Control Unit Battery Replacement Procedure
1. Turn off the alarm system by turning the keyswitch to the ‘OFF’ position.
2. Undo the unit and remove the cover.
3. Replace with a new battery of the same type.