For examples of relay behavior in DIP mode, see Figure 7 and Figure 8
on page 24. Note also the following:
- Relay operation in DIP mode is linked to RH measurement on
HMW93, and to T measurement on TMW93.
- Relay contacts are open if the transmitter is in error state (an active
error is present).
- Relay contacts are open when transmitter is powered off.
If you need to configure the relay for some other parameter or need
additional configuration options, see section Relay Configuration in
Custom Mode on page 55.