19
Installation manual remote control device VR 90 0020055329_00
4 Electrical installation
The electrical connection may only be carried out by a
suitably qualified heating engineer.
e
Danger!
Risk of fatal electric shock through contact with
live connections!
Before carrying out work on the controller,
switch off the power supply and secure it against
being switched on again.
4.2
Connecting the remote control
The remote control device communicates with the central
controller via the eBus. They can be connected to any
interface in the system. It simply has to be ensured that
the bus interfaces are eventually connected to the central
controller.
The structure of the Vaillant system allows you to lay
the eBus from component to component. This means that
the wires can be swapped without impairing
communication.
rag 1xZP Tel
BUS DCF/AF C1
2
1 2
1 2
- +
DCF 0 AF
C1
eBus
Fig 4.1 Connecting the remote control
All eBus connector plugs are designed to allow you to
wire at least 2 x 0.75 mm
2
per connection terminal.
We therefore recommend using 2 x 0.75 mm
2
eBus lines.
Electrical installation 4