Displayed menu
Explanation and setting options
A further adjustable parameter is the target room temperature, which can also be set
separately for each heating circuit. The target room temperature is taken into account
for the calculation of the heating curve. Increasing the target room temperature moves
the heating curve parallel on a 45° axis and the flow temperature is accordingly adjusted
by the control. The diagram on the left shows the relation between the target room
temperature and the heating curve.
In the basic data display you can set the language.
You can set the heating times for the heating circuit in the “Time programme”
display. Up to three heating times can be programmed per day or block. The control
operates according to the heating curve and the target room temperature. The heating
circuit has a default programme:
Mo. – Fr. 6:00 – 22:00; Sa. 7:30 – 23:30; Su. 7:30 – 22:00
Table 2.1 Adjustable parameters (continued)
Flow temperature
in °C
90
4.0 5.5
3.0
2.5
2.0
1.5
1.2
1.0
0.6
0.2
Heating curves
80
70
60
50
40
30
20
20
15
10
5
0
-5
-10
-15
-20
Outside temperature in °C
Basic data
Language
> GB english
>Select language
1
heat zone 1
3
Time programme
>Mo-Fr
>Select day of week
1
2
3
-
08:00
16:00
-
-
14:00
22:00
Operation 2