Installation manual remote control device VR 90 0020055329_00
18
If recording is required, the remote control device must
be installed in such a way that perfect recording of the
room temperature is ensured (avoiding stagnant heat, not
installed on a cold wall, etc.).
The best place for installation is usually on an inside wall
of the main living room at an approximate height of 1.5 m.
The remote control device should be able to record the
circulating air, unhindered by furniture, curtains or other
objects. Choose a location where the remote control
device is not affected by draughts from doors or windows,
or by heat sources such as radiators, chimney walls,
television sets or direct sunlight. All radiator valves must
be fully open in the room in which the remote control
device is installed if room temperature modulation is
activated.
3.2
Installing the remote control
The connection to the boiler is via twin-core Bus cable
(eBus). Lay the electrical lines up to the boiler to your
advantage before installing the remote control device.
• Drill two fixing holes (
3
) diameter 6 mm as shown in
Fig. 3.1 and insert the plugs provided.
• Guide the connection cable through the duct (
4
).
• Attach the wall plinth to the wall with the two screws
provided.
3
1
2
4
Fig. 3.1 Installation as a remote control device
• Connect the connecting cable as shown in Fig. 4.1.
• Place the remote control device (
1
) on the mounting box
so that the pins on the back of the top part fit into the
recesses (
2
).
• Push the remote control device onto the mounting box
until it engages.
3 Installation