Adapting the appliance to the heating system
76
Installation instructions geoTHERM 0020051574_04
9
9.7.1
Menu C: Set parameters for the heating
system
Display shown
Description
Factory setting
Menu C: Set parameters for the heating
system
You can set parameters for the various functions of
the heat pump in the menus C1 to C11.
Code level
C1
change
Code number:
>
0 0 0 0
Accept change?
no
>Adjust numeric character
Menu for changing the code number.
You can replace the standard code 1000
with a user-defined four-digit code here.
i
If you change the code, make a note of the
new code, otherwise you will no longer be
able to make changes in the Code level.
1000
HK2
C2
Parameters
Type
Direct circuit
Heating curve
0,30
Max. limit outs.temp.
>20 °C
Comp. starts at
-120° min
>Select temperature
HK2
C2
Parameters
Max. limit outs.temp.
>20 °C
Comp. starts at
-120° min
Minimum temperature
15 °C
Maximum temperature
43 °C
>Select temperature
If a VR 60 is connected, this menu appears several
times (for each heating circuit).
Type:
Direct circuit (for direct hydraulic systems),
Mixed circuit (for buffered hydraulic systems),
Fixed value.
Heating curve:
Adjustable heating curve (not with
fixed value).
Max limit outs.temp.:
Temperature threshold for
switching off Heating mode (summer function).
Comp.starts at:
Set the degree minutes until com-
pressor start (only with direct hydraulics).
Minimum/maximum flow temp.:
Setting the limiting
temperatures (min. and max.) that the heating
circuit can request.
The maximum flow temperature is also used to
calculate the value for the underfloor protective
circuit (maximum HC tempe compressor
hyst 2 K).
If the mixed circuit heating circuit type is set,
the underfloor protective circuit is disabled and
the factory setting is 50 °C.
Heating curve:
The heating curve represents the
relation between the outside temperature and
target flow temperature. The setting is made
separately for each heating circuit.
The efficiency and convenient operation of the
heating system significantly depend on the
selection of the correct heating curve. If too
high a heating curve is selected, the tempera-
ture in the heating system will be excessive and,
as a result, energy consumption will be higher. If
the selected heating curve is too low, the
desired temperature level may only be reached
after a while or not reached at all.
0,3
20 °C
15 °C
43 °C
9.6