Hydraulics installation
34
Installation instructions geoTHERM 0020051574_04
5
5.6
Fitting the flexible connecting hoses
b
Caution!
Risk of damage caused by leaks.
If the seals with metal support rings are not
used on the connections for the brine cir-
cuit/well water circuit (
3
) and (
4
)
(
¬
Fig.
5.8
)
, this may lead to leaks.
>
Ensure that you use the correct seals on
the connections.
– The pipes must be installed and the seals must be used
in accordance with (
¬
Fig.
5.8
)
.
– The installation must be carried out by a qualified heat-
ing engineer.
>
During the installation, observe the applicable regula-
tions.
b
Caution!
Risk of impaired function.
Air in the heating system leads to impaired
operation and reduces the heating output.
>
Fit bleed valves as required.
1
5.7 Removing the blind caps
>
Remove the blind caps (
1
) from the unit’s connections.
These are no longer required and can be properly dis-
posed of.
1
2
3
4
5.8
Fitting the flexible connecting hoses
Key
1 Heating
flow
2 Heating
return
3 From the heat source to the heat pump
4 From the heat pump to the heat source
>
Fit two of the supplied flexible connecting hoses that
have the yellow/green flat seals (from the fittings pack)
to the heating circuit connections (
1
and
2
).
>
Fit two of the supplied flexible connecting hoses that
have the seals with metal support rings (from the fittings
pack) to the brine/well water circuit connections (
3
and
4
).