42
PLANNING THE AIR/FLUE DUCT LAYOUT
Maximum flue lengths for use with ecoMAX
Accessories
Accy. No.
Vertical
flue systems
303 200 Max. permitted
concentric
flue length
Horizontal
flue systems
303 209 Max. permitted
concentric
flue length
14.0 m
13.0 m
incl.
1 elbow 87°
31.0 m
20.0 m
30.0 m
incl.
1 elbow 87°
20.0 m
incl.
1 elbow 87°
27.0 m
25.0 m
incl.
1 elbow 87°
613/2 E
618/2 E
622/2 E
pro 18 E
pro 28 E
ecoMAX
Maximum length of flue is reduced by 2.5 m for each additional 90° elbow.
Maximum length of flue is reduced by 1.0 m for each additional 45° elbow.
Maximum length of flue is reduced by 2.5 m for each additional 90° elbow
Maximum length of flue is reduced by 1.0 m for each additional 45° elbow
Accessories
Accy. No.
Vertical
flue systems
303 200 Max. permitted
concentric
flue length
Horizontal
flue systems
303 209 Max. permitted
concentric
flue length
26.0 m
25.0 m
incl.
1 elbow 87°
22.0 m
21.0 m
incl.
1 elbow 87°
29.0 m
30.0 m
incl.
1 elbow 87°
824/2 E
828/2 E
635/ E
835/ E
ecoMAX
Maximum length of flue is reduced by 2.5 m for each additional 87° elbow.
Maximum length of flue is reduced by 1.0 m for each additional 45° elbow.
Maximum length of flue is reduced by 2.5 m for each additional 90° elbow
Maximum length of flue is reduced by 1.0 m for each additional 45° elbow
834449_05GB_022005.qxd 02.02.2005 17:12 Uhr Seite 42
Содержание ecoMAX 618/2 E
Страница 2: ...834449_05GB_022005 qxd 02 02 2005 17 12 Uhr Seite 2...
Страница 58: ...Notes 834449_05GB_022005 qxd 02 02 2005 17 13 Uhr Seite 58...
Страница 59: ...Notes 834449_05GB_022005 qxd 02 02 2005 17 13 Uhr Seite 59...
Страница 60: ...834449_05 GB 02 2005 834449_05GB_022005 qxd 02 02 2005 17 13 Uhr Seite 60...