Max. permitted
concentric
flue length
Fig. 1.18
12.0 m
12.0 m
12.0 m
12.0 m
12
PLANNING THE AIR/FLUE DUCT LAYOUT
Variable
termination
kit
303 942
303 946
only in
combina-
tion with
303 933
Max. permitted
concentric
flue length
Fig. 1.19
Accessories
Accy. No.
Horizontal
flue systems
303 933 Max. permitted
concentric
flue length
Fig. 1.17
8.0 m
incl.
1 elbow 87°
plus 630
plus 831
pro 28
8.0 m
incl.
1 elbow 87°
8.0 m
incl.
1 elbow 87°
plus 624
plus 824
8.0 m
incl.
1 elbow 87°
plus 612
plus 615
plus 618
ecoTEC
Maximum length of flue is reduced by 1.0 m for each additional 87° elbow
Maximum length of flue is reduced by 0.5 m for each additional 45° elbow
Vertical
flue systems
303 900
Maximum length of flue is reduced by 1.0 m for each additional 87° elbow
Maximum length of flue is reduced by 0.5 m for each additional 45° elbow
Maximum flue lengths for use with ecoTEC
The maximum permitted concentric flue length given above is reduced as
follows:
- Reduced by 0.5 m for the variable terminal
- Reduced by 0.5 m for every 1 m VTK pipe
- Reduced by 0.5 m for every 87° bend
- Reduced by 0.5 m for 2 x 45° bend
834449_05GB_022005.qxd 02.02.2005 17:12 Uhr Seite 12
Содержание ecoMAX 618/2 E
Страница 2: ...834449_05GB_022005 qxd 02 02 2005 17 12 Uhr Seite 2...
Страница 58: ...Notes 834449_05GB_022005 qxd 02 02 2005 17 13 Uhr Seite 58...
Страница 59: ...Notes 834449_05GB_022005 qxd 02 02 2005 17 13 Uhr Seite 59...
Страница 60: ...834449_05 GB 02 2005 834449_05GB_022005 qxd 02 02 2005 17 13 Uhr Seite 60...