![Vaillant ecoMAX 618/2 E Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/vaillant/ecomax-618-2-e/ecomax-618-2-e_installation-instructions-manual_3708999026.webp)
26
INSTALLATION OF THE VARIABLE TERMINATION KIT
Variable termination kit
Accy. No.:
303 942 (black)
303 946 (white)
Contents of the kit:
• Variable terminal
• 2 x 1m pipe
• 3 x pipe support clips
• 87° bend with bird protection
grille
Important
:
The sleeve of the wall connector
must face directly upwards.
Fig. 4.1: Variable termination kit
Assembly
Before installing the flue
pipe
• Use an 8 mm screwdriver to bend
the catches inwards (fig. 4.3).
• Pull the terminal with the flue duct
out of the air duct (fig. 4.4).
Fig. 4.4: Pulling out the variable terminal
Fig. 4.3: Releasing the catch
55
Fig. 4.2
Flue Terminal Clearances
Please refer to the boiler installation
instructions for guidance about flue
terminal clearances.
834449_05GB_022005.qxd 02.02.2005 17:12 Uhr Seite 26