1
Fig. 5.12 Hooking the collector
• Place the collector with the lower edge on
the mounting rail and hook it to the clam-
ping elements.
• Make sure that the upper part (
1
) of the
clamping element is above the collector
rail.
• Tighten the clamping elements of the lower
mounting rail with the socket/combination
wrench (13 mm).
a
Caution!
After tightening the clamping ele-
ments, make sure the tension is cor-
rect by shaking the upper part of the
clamping element. If it can be moved,
retighten the nut.
1
Fig. 5.13 Peeling the film from the edges of the collector
• Lift the film at the edges of the collector.
This will facilitate pulling off the film later,
after commissioning.
H
Danger!
Danger of burning!
In case of solar irradiation inside the
units, collectors can reach
300 °C. Remove the sun protection
film installed at the factory only
after the solar energy system has
been started up.
Fig. 5.14 Removing the carrying straps
• Remove the carrying straps.