Installation manual auroTHERM 0020077994_00
Fig. 6.11 Removing the carrying straps
• Remove the carrying straps.
1
Fig. 6.12 Mounting other collectors
• Place the next collector on the lower moun-
ting rail at a distance of approx. 10 cm from
the first collector.
1
2
A
B
Fig. 6.13 Joining the collectors
• Couple the double nipple (
A
) (from the VTK
expansion module connecting kit, Part No.
0020076779) to the union nut (
B
) on the
first collector.
• Push the collectors together.
Fig. 6.14 Tightening the compression fitting
a
Caution!
Danger of damage to the collector as
a result of incorrect assembly!
To prevent damage when tightening
the compression fitting, always use a
second spanner to provide a counter
force.
• Tighten the two union nuts on the double
nipple.
Flat-roof mounting 6