19
Installation manual auroTHERM 0020077994_00
5.2.1
Bracket Type P (pantile)
A
B
1
2
1
2
5 mm
3
Fig. 5.3 Bracket type P
Key
1 Lower
bracket
2 Upper
bracket
3 Central
bracket
The bracket type P can be fixed to the
rafters
(
Pos. A
) or by use of the long rear plate set
0020080177 can be offset to suit tile profile.
Fixing to rafters
5
3
4
6
1
2
A
B
Fig. 5.4 Fixing to rafters
1. Uncover the rafters where needed. For distances
please see Tab. 5.1 and 5.2.
2. Position the bracket. Take note of the correct posi-
tions of the upper, central and lower brackets
(see Fig. 5.3).
3. Loosen the upper bolt with the socket/combination
wrench (13 mm) until the height of the bracket can be
adjusted.
4. Position the bracket at the same height of the pan-
tiles, so that the upper part of the anchor is on the
roofing, and tighten the bolt with the socket/combina-
tion wrench (13 mm).
5. Screw the bracket to the rafters with the 3 supplied
bolts.
6. Slide the pantiles back to the original position.
If necessary, adapt the water gutter on the lower (
A
)
or upper side (
B
) of the pantile with a hammer, or
suitable disk cutter, until the pantiles are tight.
d
Danger!
Risk of injury!
Always wear suitable eye protection and all
necessary personal protective equipment and
ensure the area of work is safe with regard to
other persons.
On-roof mounting 5
GB