VDF730
User
Manual
Operation
and
Display
-
59
-
Figure
4
-
8
Frequency
curve
of
direct
start
P4
-
07
(
Acceleration
/
Deceleration
mode
)
P0
-
06
(
Frequency
upper limit
)
P0
-
09
(
Acceleration
time
)
Frequency
(
f
)
Time
(
t
)
Running
command
P4
-
00
=
0
(
Direct start
)
P4
-
03
(
Startup frequency
)
P4
-
06
(
Startup
DC
braking time
)
P4
-
04
(
Startup
frequency
holding time
)
P0
-
06
(
Frequency
upper
limit
)
P0
-
09
(
Acceleration
time
)
Frequency
(
f
)
Time
(
t
)
Running
command
Default
:
P4
-
06
=
0
.
0s
P4
-
03
=
0
.
00
Hz
P4
-
04
=
0
.
0s
P4
-
07
=
0
P4
-
00
=
0
(
Direct
start
)
•
P4
-
00
=
1
(
Rotational
speed
tracking
restart
)
It
is
applicable
to
large
-
inertia
load
.
The
frequency
curve
in
this
mode
is
shown
in
the
following
fgure
.
If
the
motor
is
still
rotating
due
to
the
inertia
when
the
AC
drive
starts
,
this
mode
is
used
to
prevent
start
overcurrent
.
Figure
4
-
9
Frequency
curve
of
rotational
speed
tracking
restart
P0
-
06
(
Frequency
upper limit
)
P0
-
09
(
Acceleration
time
)
Frequency
(
f
)
Time
(
t
)
Running
command
Initial
rotational
speed
of the
load motor
P4
-
00
=
1
(
Rotational
speed
tracking
restart
)
Automatic rotational
speed tracking
detection
P0
-
06
(
Frequency
upper limit
)
P0
-
09
(
Acceleration
time
)
Frequency
(
f
)
Time
(
t
)
Running
command
Initial
rotational
speed
of
the load motor
=
0
P4
-
00
=
1
(
Rotational
speed
tracking
restart
)
Automatic
rotational
speed
tracking detection
4
.
4
.
3
Stop
Mode
The
AC
drive
supports
two
stop
modes
,
decelerate
to
stop
and
coast
to
stop
,
set
in
P4
-
10
.
Figure
4
-
10
Diagram
of
two
stop
modes
(
decelerate
to
stop
and
coast
to
stop
)
Running
frequency
P0
-
10
(
Deceleration time
)
Frequency
(
f
)
Time
(
t
)
Stop command
No
output
P4
-
11
(
Initial frequency of
stop DC braking
)
P4
-
12
(
Waiting
time of
stop DC
braking
)
P4
-
14
(
Stop DC
braking time
)
P4
-
13
(
Stop DC
braking current
, %)
P4
-
10
=
0
:
Decelerate
to stop
Default values
:
P4
-
10
=
0
P4
-
11
=
0
.
00 Hz
P4
-
12
=
0
.
0s
;
P4
-
13
=
0
%;
P4
-
14
=
0
.
0s
Running
frequency
Rotational
speed
under load
,
coast
to stop by inertia
Frequency
(
f
)
Time
(
t
)
Stop command
P4
-
10
=
1
:
Coast to stop
Содержание VDF730 Series
Страница 1: ...VDF730 Series...
Страница 7: ......
Страница 8: ...1 Safety Information and Precautions...
Страница 15: ...Safety Information and Precautions VDF730 User Manual 14...
Страница 16: ...2 Product Information...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 51: ...Mechanical and Electrical Installation VDF730 User Manual 50...
Страница 52: ...4 Operation and Display...
Страница 75: ...Operation and Display VDF730 User Manual 74...
Страница 76: ...5 Function Code Table...
Страница 97: ...Function Code Table VDF730 User Manual 96...
Страница 98: ...6 Description of Function Codes...
Страница 153: ...Description of Function Codes VDF730 User Manual 152...
Страница 154: ...7 EMC...
Страница 158: ...8 Troubleshooting...
Страница 165: ...Troubleshooting VDF730 User Manual 164...